Distal Clavicle Autograft Versus Traditional and Congruent Arc Latarjet Procedures: A Comparison of Surface Area and Glenoid Apposition With 3-Dimensional Computed Tomography and 3-Dimensional Magnetic Resonance Imaging

Author:

Kim Billy I.1,Hudson Caroline P.1,Taylor Dean C.1,Anakwenze Oke1,Dickens Jonathan F.1,Lau Brian C.1

Affiliation:

1. Department of Orthopaedic Surgery, Duke University, Durham, North Carolina, USA

Abstract

Background: Limited studies have compared graft-glenoid apposition and glenoid augmentation area between the Latarjet procedure and distal clavicle graft in glenohumeral stabilization. Additionally, preoperative planning is typically performed using computed tomography (CT), and few studies have used 3-dimensional (3D) magnetic resonance imaging (MRI) reformations to assess graft dimensions. Purpose: The purpose of this study was 2-fold: (1) to compare bony apposition, glenoid augmentation, and graft width among coracoid and distal clavicle bony augmentation techniques and (2) to determine the viability of 3D MRI to assess bone graft dimensions. Study Design: Controlled laboratory study. Methods: A total of 24 patients with recurrent glenohumeral instability and bone loss were included in this study. 3D CT and 3D MRI reformations were utilized to measure pertinent dimensions for 5 orientations of coracoid and distal clavicle autografts: (1) standard Latarjet procedure (SLJ), (2) congruent arc Latarjet procedure (CLJ), (3) distal clavicle attached by its posterior surface (DCP), (4) distal clavicle attached by its inferior surface (DCI), and (5) distal clavicle attached by its resected end (DCR). Glenoid augmentation was defined as the graft surface area contributing to the glenoid. Bone-on-bone apposition was defined as the graft-glenoid contact area for bone healing potential, and graft width was pertinent for fixation technique. Glenoid bone loss ranged from 0% to 34%. Paired t tests were used to compare graft sizes between patients and compare 3D CT versus 3D MRI measurements. Results: The CLJ had the largest graft surface area (mean, 318.41 ± 74.44 mm2), while the SLJ displayed the most bone-on-bone apposition (mean, 318.41 ± 74.44 mm2). The DCI had the largest graft width (mean, 20.62 ± 3.93 mm). Paired t tests revealed no significant differences between the Latarjet techniques, whereas distal clavicle grafts varied significantly with orientation. All 3D CT and 3D MRI measurements were within 1 mm of each other, and only 2 demonstrated a statistically significant difference (coracoid width: 13.03 vs 13.98 mm, respectively [ P = .010]; distal clavicle thickness: 9.69 vs 10.77 mm, respectively [ P = .002]). 3D CT and 3D MRI measurements demonstrated a strong positive correlation ( r > 0.6 and P < .001 for all dimensions). Conclusion: Glenoid augmentation, bony apposition, and graft width varied with coracoid or distal clavicle graft type and orientation. Differences between 3D CT and 3D MRI were small and likely not clinically significant. Clinical Relevance: 3D MRI is a viable method for preoperative planning and graft selection in glenoid bone loss.

Funder

arthrex

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3