Comparison of Cutaneous and Transosseous Electromagnetic Position Sensors in the Assessment of Tibial Rotation in a Cadaveric Model

Author:

Magit David P.1,McGarry Michelle2,Tibone James E.1,Lee Thay Q.2

Affiliation:

1. Kerlan Jobe Orthopaedic Clinic, Los Angeles, California

2. Orthopaedic Biomechanics Laboratory, VA Long Beach Healthcare System, Long Beach, and University of California, Irvine, Long Beach, California

Abstract

Background Recent studies have highlighted the growing interest in validating anatomic anterior cruciate ligament reconstructions. A simple method of measuring tibial rotation is necessary to provide an objective clinical assessment of restoration of normal knee kinematics after various anterior cruciate ligament reconstructive techniques. Objective To validate a new method of measuring tibial rotation by comparing cutaneous with transosseous electromagnetic position sensors during a simulated standard knee examination. Study Design Controlled laboratory study. Methods Eight thawed, fresh-frozen cadaveric knee specimens with skin and soft tissues preserved were mounted on the femoral side in neutral rotation by a rigid clamp, allowing 6 degrees of freedom of the knee joint. With the knee fixed at 30° of flexion, a series of maximal manual internal and external tibial rotations were performed and measured with an electromagnetic tracking system that measures 6 degrees of freedom in a Cartesian coordinate system. During each series of measurements, a cutaneous transmitter was fixed overlying the tibial tuberosity. Simultaneously, a second transducer was rigidly fixed to a transosseous pin placed just distal to the tibial tubercle. Measurements were repeated at 90° of flexion. Differences in measurements were assessed. Results No significant differences were found with maximal internal and external rotation between cutaneous and transosseous measurements at 30° of knee flexion (13.0° vs 14.5°, P = .4) or at 90° of flexion (11.2° vs 12.9°, P = .5). Correlation ( R) between cutaneous and transosseous measurements at 30° was .97 ( P = .00009) and at 90° was .99 ( P < .00001). The accuracy of cutaneous measurements using transosseous as the known was 1.6° ± 1.3°. Repeatability of cutaneous measurements was 0.8° ± 0.4°. The repeatability of transosseous measurements was 1.0° ± 0.5°. Conclusion No significant differences were found at either 30° or 90° of flexion when measuring tibial rotation using cutaneous versus transosseous electromagnetic position sensors. Clinical Relevance The ability to measure knee rotation using cutaneous electromagnetic position sensors represents a promising new method for assessing various clinical conditions and surgical outcomes.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3