Augmented Ulnar Collateral Ligament Repair With Structural Bioinductive Scaffold: A Biomechanical Study

Author:

Lin Kenneth M.1,Brinson Kenneth2,Atzmon Ran3,Chan Calvin K.1,Sherman Seth L.1,Safran Marc R.1,Freehill Michael T.1

Affiliation:

1. Department of Orthopaedic Surgery, Division of Sports Medicine, Stanford University, Redwood City, California, USA

2. School of Medicine, Stanford University, Redwood City, California, USA

3. Department of Orthopaedic Surgery, Assuta Ashdod Medical Centre, Ashdod, Israel

Abstract

Background: Elbow ulnar collateral ligament (UCL) repair with suture brace augmentation shows good time-zero biomechanical strength and a more rapid return to play compared with UCL reconstruction. However, there are concerns about overconstraint or stress shielding with nonabsorbable suture tape. Recently, a collagen-based bioinductive absorbable structural scaffold has been approved by the Food and Drug Administration for augmentation of soft tissue repair. Purpose/Hypothesis: This study aimed to assess the initial biomechanical performance of UCL repair augmented with this scaffold. We hypothesized that adding the bioinductive absorbable structural scaffold to primary UCL repair would impart additional time-zero restraint to the valgus opening. Study Design: Controlled laboratory study. Methods: Eight cadaveric elbow specimens—from midforearm to midhumerus—were utilized. In the native state, elbows underwent valgus stress testing at 30o, 60o, and 90o of flexion, with a cyclical valgus rotational torque. Changes in valgus rotation from 2- to 5-N·m torque were recorded as valgus gapping. Testing was then performed in 4 states: (1) native intact UCL—with dissection through skin, fascia, and muscle down to an intact UCL complex; (2) UCL-transected—distal transection of the ligament off the sublime tubercle; (3) augmented repair with bioinductive absorbable scaffold; and (4) repair alone without scaffold. The order of testing of repair states was alternated to account for possible plastic deformation during testing. Results: The UCL-transected state showed the greatest increase in valgus gapping of all states at all flexion angles. Repair alone showed similar valgus gapping to that of the UCL-transected state at 30° ( P = .62) and 60° of flexion ( P = .11). Bioinductive absorbable scaffold–augmented repair showed less valgus gapping compared with repair alone at all flexion angles ( P = .021, P = .024, and P = .024 at 30°, 60°, and 90°, respectively). Scaffold-augmented repair showed greater gapping compared with the native state at 30° ( P = .021) and 90° ( P = .039) but not at 60° of flexion ( P = .059). There was no difference when testing augmented repair or repair alone first. Conclusion: UCL repair augmented with a bioinductive, biocomposite absorbable structural scaffold imparts additional biomechanical strength to UCL repair alone, without overconstraint beyond the native state. Further comparative studies are warranted. Clinical Relevance: As augmented primary UCL repair becomes more commonly performed, use of an absorbable bioinductive scaffold may allow for improved time-zero mechanical strength, and thus more rapid rehabilitation, while avoiding long-term overconstraint or stress shielding.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3