The biomechanics of lateral knee bracing

Author:

France E. Paul1,Paulos Lonnie E.2,Jayaraman Gopal3,Rosenberg Thomas D.2

Affiliation:

1. Salt Lake City Knee and Sports Medicine Clinic, Department of Orthopedics, University of Utah School of Medicine, Salt Lake City, Utah

2. Salt Lake City Knee and Sports Medicine Clinic

3. Department of Mechanical Engineering, Michigan Technological University, Houghton, Michigan

Abstract

In Part I of our study on lateral knee bracing, we evaluated brace effectiveness using cadaveric knees and two commercially available braces (McDavid and Omni). The results indicated that for low-rate dynamic valgus loading, neither brace provided significant pro tection against MCL injury. Also, four potentially ad verse effects were noted. The goals in Part II were to: 1) determine the clinical significance of brace induced MCL preload; 2) define the functional character of an "ideal" brace; 3) design and validate a surrogate knee model for testing brace effectiveness; and 4) determine brace performance under impact loading using the sur rogate knee and six commercially available brace types (manufactured by DonJoy, McDavid, Mueller, Omni Sci entific, Stromgren-Scott, and Tru-Fit). Knee braces, modified to measure varus/valgus bending force, were used to determine MCL preload effects in 13 human volunteers. An anatomically correct surrogate knee model, instrumented to measure ligament/tendon ten sion and medial joint opening, was developed and validated using information from our previous cadaver studies and results of analyses on the effects of high strain rates (100% versus 1000% strain/sec) on MCL failure. Over 500 impact tests were performed on the surrogate knee in unbraced versus braced conditions. Tests were conducted for three impactor masses, two flexion angles, and free or constrained limb positions. Impact safety factors (ISF) were calculated for each test condition and brace type. An ISF of 1.50 (MCL load reduction of 30%) was considered significant. The results were: 1) brace induced MCL preload in vivo was negated by joint compressive forces; 2) the "ideal" brace should increase the lateral force at MCL injury by 80%; 3) at a 1000% strain/sec strain rate, MCL failure force was increased by 28%; and 4) on the average, only one brace exceeded the minimum ISF (DonJoy, average ISF = 1 .51 ).

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Reference12 articles.

Cited by 53 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3