Subacromial Balloon Spacer Implantation for Massive Irreparable Rotator Cuff Tears Is Associated With Restoration of the Acromiohumeral Interval and Glenohumeral Center of Pressure: A Systematic Review and Meta-Analysis of Controlled Laboratory Studies

Author:

Kunze Kyle N.12ORCID,Moran Jay3ORCID,Taylor Samuel A.12,Fu Michael C.12,Rodeo Scott A.12ORCID,Warren Russell F.12,Dines David M.12,Gulotta Lawrence V.12,Dines Joshua S.12

Affiliation:

1. Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York, USA

2. Sports Medicine and Shoulder Institute, Hospital for Special Surgery, New York, New York, USA

3. Yale School of Medicine, New Haven, Connecticut, USA

Abstract

Background: Biodegradable subacromial balloon spacers (SBSs) have become increasingly used for the treatment of massive irreparable rotator cuff tears given their theorized clinical benefits; however, the relationship between biomechanical functions of the balloon spacer and clinical benefits remains unclear. Purpose: To perform a systematic review and meta-analysis of controlled laboratory studies investigating the use of SBSs for massive irreparable rotator cuff tears. Study Design: Systematic review and meta-analysis; Level of evidence, 4. Methods: PubMed, OVID/Medline, and Cochrane databases were queried in July 2022 for biomechanical data pertaining to SBS implantation in cadaveric models of irreparable rotator cuff tears. Random-effects meta-analysis of continuous outcomes using the DerSimonian-Laird method was performed to estimate pooled-treatment effect sizes between the irreparable rotator cuff tear state and the state in which an SBS was implanted. Data reported variably or in formats not amenable to analysis were presented descriptively. Results: Five studies involving 44 cadaveric specimens were included. At 0° of shoulder abduction, SBS implantation resulted in a mean inferior humeral head translation of 4.80 mm (95% CI, 3.20-6.40; P < .001) relative to the irreparable rotator cuff tear state. This decreased to 4.39 mm and 4.35 mm at 30° and 60° of abduction, respectively. At 0° of abduction, implantation of an SBS was associated with a 5.01-mm (95% CI, 3.56-6.46, P < .001) anterior translation of the glenohumeral center of contact pressure relative to the irreparable tear state. This translation changed to 5.11 mm and 5.49 mm at 30° and 60° of abduction. In 2 studies, SBS implantation restored the glenohumeral contact pressure to that of the intact state and significantly reduced subacromial pressure distribution over a rotator cuff repair state. In 1 study, a high balloon fill volume (40 mL) resulted in a significant 10.3 ± 1.4–mm more anterior humeral head position relative to the intact cuff state. Conclusion: SBS implantation in cadaveric models of irreparable rotator cuff tears results in significant improvements in humeral head position at 0°, 30°, and 60° of shoulder abduction. Balloon spacers may also improve glenohumeral and subacromial contact pressures, although insufficient evidence currently exists to corroborate these findings. High balloon fill volumes (40 mL) may confer supraphysiologic anteroinferior translation of the humeral head.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3