The Impact of Radiologist Screening Mammogram Reading Volume on Performance in the Ontario Breast Screening Program

Author:

Walker Meghan J.12,Hartman Krystal1,Majpruz Vicky1,Leung Yvonne W.1,Fienberg Samantha134,Rabeneck Linda1256,Chiarelli Anna M.12

Affiliation:

1. Prevention and Cancer Control, Ontario Health (Cancer Care Ontario), Toronto, Ontario, Canada

2. Dalla Lana School of Public Health, University of Toronto, Toronto, Ontario, Canada

3. Radiology, McMaster University, Hamilton, Ontario, Canada

4. Medical Imaging, Grand River Hospital, Kitchener, Ontario, Canada

5. Department of Medicine, University of Toronto, Toronto, Ontario, Canada

6. IC/ES, Toronto, Ontario, Canada

Abstract

Purpose: Although some studies have shown increasing radiologists’ mammography volumes improves performance, there is a lack of evidence specific to digital mammography and breast screening program performance targets. This study evaluates the relationship between digital screening volume and meeting performance targets. Methods: This retrospective cohort study included 493 radiologists in the Ontario Breast Screening Program who interpreted 1,762,173 screening mammograms in participants ages 50-90 between 2014 and 2016. Associations between annual screening volume and meeting performance targets for abnormal call rate, positive predictive value (PPV), invasive cancer detection rate (CDR), sensitivity, and specificity were modeled using mixed-effects multivariate logistic regression. Results: Most radiologists read 500-999 (36.7%) or 1,000-1,999 (31.0%) screens annually, and 18.5% read ≥2,000. Radiologists who read ≥2,000 annually were more likely to meet abnormal call rate (OR = 3.85; 95% CI: 1.17-12.61), PPV (OR = 5.36; 95% CI: 2.53-11.34), invasive CDR (OR = 4.14; 95% CI: 1.50-11.46), and specificity (OR = 4.07; 95% CI: 1.89-8.79) targets versus those who read 100-499 screens. Radiologists reading 1,000-1,999 screens annually were more likely to meet PPV (OR = 2.32; 95% CI: 1.22-4.40), invasive CDR (OR = 3.36; 95% CI: 1.49-7.59) and specificity (OR = 2.00; 95% CI: 1.04-3.84) targets versus those who read 100-499 screens. No significant differences were observed for sensitivity. Conclusions: Annual reading volume requirements of 1,000 in Canada are supported as screening volume above 1,000 was strongly associated with achieving performance targets for nearly all measures. Increasing the minimum volume to 2,000 may further reduce the potential limitations of screening due to false positives, leading to improvements in overall breast screening program quality.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Breast Mammographic Screening: The More Mammograms Read, the Better the Performance;Canadian Association of Radiologists Journal;2021-09-05

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3