Low Tube Voltage Chest Computed Tomography With Enhancement Using Low-Concentration Iodinated Contrast Media: Comparison of 240 mg/mL Versus 300 mg/mL Iodinated Contrast Media

Author:

Chang Suyon1ORCID,Jung Jung Im1,Beck Kyongmin S.1ORCID

Affiliation:

1. Department of Radiology, Seoul St Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea

Abstract

Purpose: To evaluate the image quality of low voltage chest computed tomography with enhancement (CECT) using low-concentration-iodine contrast media (LCCM). Method: From 9 December to 19 December 2019, three different protocols were used for 263 patients undergoing chest CECT. Chest CECT was done using routine (300 mgI/ml contrast media with 100 kVp) protocol (group 1), LCCM (240 mgI/ml contrast media)–100 kVp protocol (group 2) and LCCM–80 kVp protocol (group 3) in 91, 97 and 75 patients, respectively. The overall diagnostic acceptability, anatomical depiction, noise and contrast-related artifacts were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and figure of merit (FOM) in the aorta and the main pulmonary trunk were measured. Results: The overall diagnostic acceptability scores were not significantly different between groups 1 and 2 ( P = .261); group 3 demonstrated significantly lower overall diagnostic acceptability score compared with group 1 ( P = .011) or group 2 ( P < .001). However, in CECT with iterative reconstruction (IR), the overall diagnostic acceptability scores did not show significant difference among 3 groups. Group 3 showed significantly lower effective radiation dose compared with group 1 (2.33 vs 1.22 mSv, P < .001) or group 2 (2.28 vs .22 mSv, P < .001). Conclusions: In 100 kVp chest CECT, the image quality of using 240 mg/mL iodinated contrast media is comparable to that using 300 mg/mL iodine contrast media, regardless of application of IR; with IR, chest CECT using 80 kVp and 240 mg/mL iodinated contrast media results in acceptable image quality and lower radiation dose.

Funder

TAEJOON PHARM Co Ltd, South Korea

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3