Dosimetric Feasibility of Cone-Beam CT in Pediatric Image-Guided Retrograde Gastrostomy Tube Insertions

Author:

Shkumat Nicholas A.12,Brashdi Yahya Al12,Volodina Sabina1,Parra Dimitri12,Connolly Bairbre L.12

Affiliation:

1. Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto, Ontario, Canada

2. Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada

Abstract

Purpose: Cone-beam computed tomography (CBCT) in interventional radiology allows volumetric imaging with open patient access. This work aimed to assess radiation dose metrics of CBCT in simulated image-guided retrograde gastrostomy (IGRG) tube insertions in pediatric anthropomorphic phantoms and to compare them to measured radiation dose metrics obtained using fluoroscopy during clinical IGRG tube insertions in children. Methods: Radiation dose indices obtained from radiation dose structured reports of fluoroscopic IGRG tube insertions were retrospectively evaluated in a consecutive cohort of 30 children. Dose indices were fractionated into 3 clinical stages for each procedure ( planning, insertion, and confirmation). These 3 stages in 30 patients (3 × 30 = 90 patient stages) were compared to dose indices measured from 4 CBCT acquisition protocols acquired in pediatric phantoms. Results: The mean proportion of radiation dose during planning, insertion, and confirmation was 35%, 38% and 27%, with mean reference-point air kerma (range) measured to be 1.0 (0.02-6.0) mGy, 0.9 (0.03-4.1) mGy, and 0.7 (0.04-3.7) mGy, respectively. Cone-beam computed tomography dose varied greatly depending on technical parameters and protocol selection, ranging from 0.7 to 39.3 mGy. In 19% of patient stages, the most dose-sparing CBCT protocol evaluated on phantoms delivered less radiation than the radiation dose indices recorded from patient’s fluoroscopy. Conclusions: From a dosimetric perspective, radiation delivered in CBCT can vary widely, yet can be appreciably low. With appropriate CBCT protocol selection, the radiation dose delivered may be sufficiently low to warrant consideration for use, if clinically needed during difficult IGRG tube insertions, and satisfy the interventionalist’s benefit–risk assessment.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3