Abstract

Of the first 2000 incidents reported to the Australian Incident Monitoring Study, 1256 occurred in relation to general anaesthesia and 81 of the latter were first detected by blood pressure (BP) monitoring. A further 25 incidents not associated with general anaesthesia were first detected by blood pressure monitoring, giving a total of 106. In the monitor detection of incidents in relation to general anaesthesia, BP monitoring ranked fourth after oximetry, capnography and low pressure alarms. On the other hand, 38 incidents in which the problem was primarily one of significant change in BP were first detected by means other than the BP monitor (20 clinically, 12 by pulse oximetry and 6 by ECG). Early detection rates of hypotension were 60% for invasive methods, 40% for automated non-invasive (NIBP) devices and 30% for manual sphygmomanometry. There were 21 reports of BP monitor “failure”; the 11 of these which occurred with NIBPs involved unexplained false “low” or “high” readings and failure to detect profound hypotension, and led to considerable morbidity and at least one death. The 10 cases of invasive monitoring failure were predominantly due to mains power loss, hardware breakage or operator error. In a theoretical analysis of the 1256 GA incidents, it was considered that on its own, BP monitoring would have detected 919 (73%), but in the vast majority, by the time this detection has occurred, potential organ damage could not be excluded. It is recommended that BP be measured at regular intervals dictated by clinical requirements (usually at least every five minutes). BP monitoring should be supplemented by other modalities in accordance with the College of Anaesthetists guidelines and when immediate and reliable detection of change in BP is critical, invasive monitoring should be used.

Publisher

SAGE Publications

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

Cited by 22 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. The Patient With Cardiovascular Disease for Lung Resection Surgery;Cohen's Comprehensive Thoracic Anesthesia;2022

2. Cardiovascular Monitoring in Postoperative Care of Adult Cardiac Surgical Patients;Postoperative Critical Care for Adult Cardiac Surgical Patients;2018

3. What is the definition of intraoperative hypotension in dogs? Results from a survey of diplomates of the ACVAA and ECVAA;Veterinary Anaesthesia and Analgesia;2015-01

4. Cardiovascular Monitoring;Postoperative Critical Care for Cardiac Surgical Patients;2013-10-31

5. Preoperative Risk Assessment and Intraoperative Monitoring;General Surgery Risk Reduction;2013-09-18

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3