High-sensitivity cardiac troponin release after conventional and minimally invasive cardiac surgery

Author:

De Mey Nathalie1,Cammu Guy1ORCID,Brandt Inger2,Belmans Ann3,Van Mieghem Carlos4,Foubert Luc1,De Decker Koen1

Affiliation:

1. Departments of Anaesthesia and Critical Care Medicine, OLV Hospital, Aalst, Belgium

2. Department of Clinical Chemistry, OLV Hospital, Aalst, Belgium

3. Department of I-BioStat, University Hospital of Leuven and Hasselt, Leuven, Belgium

4. Department of Cardiology, OLV Hospital, Aalst, Belgium

Abstract

After cardiac surgery, a certain degree of myocardial injury is common. The arbitrarily proposed biomarker cut-off point in the Third Universal Definition for diagnosing coronary artery bypass grafting (CABG)–related perioperative myocardial infarction (PMI) is controversial and unvalidated for non-CABG surgery. Minimally invasive cardiac surgery is often thought to be associated with less myocardial damage compared to conventional surgical approaches. We conducted a real-life prospective study with serial sampling of high-sensitivity cardiac troponin T (hs-cTnT) in patients undergoing conventional and minimally invasive cardiac surgery. Four different types of cardiac surgery were performed in 400 patients (February 2014–January 2015): CABG, aortic valve replacement, minimally invasive mitral/tricuspid valve surgery through the HeartPort (HP) technique and combined CABG/valve surgery. Each group was further subdivided for comparison between the different surgical techniques. Blood samples were collected consecutively at intensive care unit (ICU) admission and 3, 6, 9, 12, 18, 24 and 48 h thereafter. The hs-cTnT values by peak timepoint differed significantly depending on the surgical approach. The overall peak timepoint for hs-cTnT occurred 6 h after ICU admission. The combined surgery and multiple-valve HP groups had the highest values (medians of 1067.5 (744.9–1455) ng/L and 1166 (743.7–2470) ng/L, respectively). The peak hs-cTnT values for patients developing PMI showed high variability. Differentiation between cardiac surgery–related necrosis and PMI remains challenging. This study emphasizes the importance of a clinically reliable biomarker cut-off value in addition to electrocardiography and echocardiography to optimize PMI diagnosis.

Publisher

SAGE Publications

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3