An Audit of the Diagnostic Accuracy of Rotational Thromboelastometry for the Identification of Hypofibrinogenaemia and Thrombocytopenia during Cardiopulmonary Bypass

Author:

Matzelle S. A.1,Weightman W. M.1,Gibbs N. M.1

Affiliation:

1. Department of Anaesthesia, Sir Charles Gairdner Hospital, Perth, Western Australia

Abstract

We audited the diagnostic accuracy of ROTEM® (TEM Innovations, GmbH, Munich, Germany) measurements of hypofibrinogenaemia (fibrinogen <1.5 g/l) and thrombocytopenia (platelet count <100 × 109/l) in 200 adult non-transplant patients during cardiopulmonary bypass (CPB). Blood samples were obtained for FIBTEM (assay for the fibrin part of the clot), PLTEM (calculated platelet-specific component), and laboratory measurements simultaneously. Our thresholds for FIBTEM and PLTEM were A10 (clot firmness 10 minutes after clotting time) ≤8 mm, and <35 mm respectively. We also calculated the accuracy of smaller thresholds and earlier indices. We found that FIBTEM A10 ≤8 mm had low sensitivity (0.62) for hypofibrinogenaemia. With the 13% hypofibrinogenaemia prevalence in our sample, the positive predictive value (PPV) was 0.47. In contrast, FIBTEM A10 ≤8 mm had higher specificity (0.90) (negative predictive value [NPV] 0.94). Of the other FIBTEM values analysed, only A5 ≤6 mm had similar or superior accuracy. The PLTEM results were less encouraging (sensitivity 0.81, specificity 0.62). With our prevalence of thrombocytopenia (also 13%), the PPV was only 0.24. However, the NPV was high (0.96). Of the other PLTEM values analysed, only A5 <25 mm had similar or superior accuracy. These findings indicate that during CPB FIBTEM A10 ≤8 mm and PLTEM A10 <35 mm have greater accuracy in identifying the absence of hypofibrinogenaemia and thrombocytopenia respectively than their presence. On the basis of these results we would be reassured by FIBTEM A10 values >8 mm and PLTEM A10 values ≥35 mm, but would continue to use laboratory measurements for confirmation. We would not use FIBTEM A10 ≤8 mm or PLTEM A10 <35 mm values alone to guide replacement therapy unless clinical conditions warranted an immediate decision before laboratory measurements were available.

Publisher

SAGE Publications

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3