The Incidence and Risk of Central Venous Catheter Malpositioning: A Prospective Cohort Study in 1619 Patients

Author:

Pikwer A.12,Bååth L.13,Davidson B.14,Perstoft I.15,Åkeson J.16

Affiliation:

1. Departments of Anaesthesiology and Intensive Care Medicine, and of Diagnostic Radiology, Lund University, Malmö University Hospital, Malmö, Sweden

2. Resident Anaesthesiologist, Department of Anaesthesiology and Intensive Care Medicine.

3. Consultant Radiologist, Department of Diagnostic Radiology.

4. Consultant Anaesthesiologist, Department of Anaesthesiology and Intensive Care Medicine.

5. Nurse Anesthetist and IT Technician, Department of Anaesthesiology and Intensive Care Medicine.

6. Associate Professor and Consultant Anaesthesiologist, Department of Anaesthesiology and Intensive Care Medicine.

Abstract

Central venous catheters are used in various hospital wards. An anterior-posterior chest X-ray is usually obtained soon after cannulation to assess the location of the catheter tip. This prospective clinical study was designed to determine the radiographic catheter tip position after central venous cannulation by various routes, to identify clinical problems possibly associated with the use of malpositioned catheters and to make a cost-benefit analysis of routine chest X-ray with respect to catheter malposition. A total 1619 central venous cannulations were recorded during a three-year period with respect to patient data, information about the cannulation procedures, the radiographic catheter positions and complications during clinical use. The total incidence of radiographic catheter tip malposition, defined as extrathoracic or ventricular positioning, was 3.3% (confidence interval 2.5 to 4.3%). Cannulation by the right subclavian vein was associated with the highest risk of malposition, 9.1%, compared with 1.4% by the right internal jugular vein. Six of the 53 malpositioned catheters were removed or adjusted. No case of malposition was associated with vascular perforation, local venous thrombosis or cerebral symptoms. We conclude that the radiographic incidence of central venous catheter malpositioning is low and that clinical use of malpositioned catheters is associated with few complications. However, determination of the catheter position by chest X-ray should be considered when mechanical complications cannot be excluded, aspiration of venous blood is not possible, or the catheter is intended for central venous pressure monitoring, high flow use or infusion of local irritant drugs.

Publisher

SAGE Publications

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3