Relative Reliability of the Auditory Evoked Potential and Bispectral Index for Monitoring Sedation Level in Surgical Intensive Care Patients

Author:

Lu C.-H.1,Ou-yang H.-Y.1,Man K.-M.12,Hsiao P.-C.1,Ho S.-T.1,Wong C.-S.1,Liaw W.-J.1

Affiliation:

1. Department of Anesthesiology, Tri-Service General Hospital National Defense Medical Center, Taipei, Taiwan

2. Department of Anesthesiology, Tungs’ Taichung MetroHarbor Hospital, Taiwan.

Abstract

Sedation is an important adjunct therapy for patients in the intensive care unit. The objective of the present study was to observe correlation between an established subjective measure, the Ramsay Sedation Scale, and two objective tools for monitoring critically ill patients: the Bispectral Index (BIS) and auditory evoked potential. Ninety patients undergoing major surgery scheduled for postoperative mechanical ventilation and continuous sedation with propofol and fentanyl were selected. Electrodes for determining BIS and auditory evoked potential were placed on the foreheads of all patients according to manufacturer's specifications at least six hours after patients’ arrival at the intensive care unit. Ramsay Sedation Scale, BIS, signal quality index, composite A-line autoregressive index (AAI) and electromyographic activities were recorded every five minutes for 30 minutes. BIS and AAI showed good correlation amongst readings (rs=0.697, P <0.07). Both were significantly influenced by electromyographic activities (BIS, rs=0.735, P <0.07; AAI, rs=0.856, P <0.07). Comparison of BIS and AAI revealed an acceptable correlation between electroencephalogram variables and the Ramsay Sedation Scale (BIS, τ=-0.689; AAI, τ=-0.621; P <0.07). In conclusion, the auditory evoked potential and BIS monitors revealed an acceptable correlation with the Ramsay Sedation Scale. However, the BIS and auditory evoked potential monitors do not perform adequately as a substitute in the assessment of sedated intensive care unit patients. These monitors could be used as part of an integrated approach for the evaluation of those patients especially when the subjective scales do not work well in the setting of neuromuscular blockade or may not be sufficiently sensitive to evaluate very deep sedation.

Publisher

SAGE Publications

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3