Investigation on residual-related error and the effect of solution properties using protective devices for the reconstitution of cytotoxic agents in actual situations

Author:

Hama Koji1,Kitada Noriaki2,Fukushima Koichi2,Hashida Tohru2,Kataoka Kazusaburo3

Affiliation:

1. Department of Pharmacy, Kobe City Medical Center General Hospital, Kobe, Hyogo, Japan,

2. Department of Pharmacy, Kobe City Medical Center General Hospital, Kobe, Hyogo, Japan

3. School of Pharmacy and Pharmaceutical Sciences, Mukogawa Women's University, Nishinomiya, Hyogo, Japan

Abstract

Purpose. Three products can be used in Japan for the reconstitution of cytotoxic agents: PhaSeal, Chemo CLAVE and Chemo Mini Spike (CMS). The low preparation volume may be affected by residual-related volume in their devices. In this study, the residual-related error in their devices was examined and compared. Method. The blank of each component of these devices was weighed using a precision electric balance. After ejecting distilled water (DW) for injection, each was weighed again with the balance. In addition, for etoposide in the cases of PhaSeal and Chemo CLAVE, the components of the devices were similarly weighed. Result. The weight gains of each device after ejecting DW were as follows: CMS-V (440 mg) greater than the combined components of Chemo CLAVE (128—171 mg)/CMS-MT (123 mg) greater than the combined components of PhaSeal (13—56 mg). For etoposide, the weight gains of PhaSeal (208 mg) and Chemo CLAVE (223 mg) showed no significant difference. The priming volume of each device was calculated from the specific gravity of water. The residual-related volume was ‘CMS-V > Chemo CLAVE, CMS-MT > PhaSeal’, although this was very slight in actual situations. Conclusion. The residual-related volume was marked in its low preparation volume. In water-soluble drugs, the residual volume of PhaSeal was lowest of the devices in this study, but in viscous drugs, such as etoposide, the residual volume of PhaSeal was almost identical to Chemo CLAVE; that is, the residual volume of these devices was affected by the solution property. The residual-related volume in the devices will lead to errors; therefore, residual-related errors need to be considered in the use of these devices.

Publisher

SAGE Publications

Subject

Pharmacology (medical),Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3