Stress Analysis of Implant-Supported Removable Partial Denture with Anterior Fixed Prostheses and Conventional Implant-Supported Overdentures in the Edentulous Mandible

Author:

Ozel Gulsum Sayin1ORCID,Ozyilmaz Ozgun Yusuf2,Inan Ozgur3

Affiliation:

1. Department of Prosthodontics, School of Dentistry, Istanbul Medipol University, Bagcilar, Istanbul, Turkey

2. Faculty of Dentistry, Department of Prosthodontics, Bezmialem Vakif University, Istanbul, Turkey

3. Faculty of Dentistry, Department of Prosthodontics, Selcuk University, Konya, Turkey

Abstract

Aim: To compare new design implant-supported removable partial dentures retained with anterior fixed prosthesis with a conventional locater and bar attached implant overdenture prostheses retained by two or four implants via photoelastic stress analysis. Materials and Methods: Seven edentulous mandibuler acryclic models prepared and divided into two main groups; two to four implant models, subgroup separation as stated; for two implant models overdenture with locator attachment, crown design retained removable prosthesis with clasp retention, bridge design retained removable prosthesis with clasp retention, bridge design retained removable prosthesis with precision attachment retention; and for four implant models prosthesis with bar attachment overdenture, fixed bridge design retained removable prosthesis with clasp retention, fixed retained removable prosthesis with precision attachment retention. A 300 N load was applied to the first premolars. Photoelastic stress analysis method that is a specific method concerning stress visualization, and does not require statistical analysis, was used. The stress distributions were seen in optically using a poloriscope. Results: In the models with two implant-retained removable partial dentures, the stress distribution was found to be lower than that with the four implant-retained removable partial dentures. Nonsplinted implants caused high stress around the distal implant on the loading side. Conclusion: The stress loads were transmitted to other implants by splinting. Implant-supported removable partial dentures with an anterior fixed prosthetic design show lower stress distributions compared with bar retained prosthesis. These dentures appear to be advantageous in terms of stress transmission.

Publisher

SAGE Publications

Subject

Pharmacology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3