Comparison of the Marginal and Internal Discrepancy of Metal-Ceramic Restorations Produced by Milling for Soft Metal, Direct Metal Laser Sintering and Casting Methods: An In Vitro Study

Author:

Aydın Nazlı12ORCID,Ekren Orhun13,Kocak Elif Figen12,Ucar Yurdanur4

Affiliation:

1. Department of Prosthetic Dentistry, Faculty of Dentistry, Cukurova University, Balcali, Adana, Turkey

2. Abdi Sutcu Vocational School of Health Services, Cukurova University, Balcali, Adana, Turkey

3. Department of Advanced Materials and Nanotechnology, Institute of Natural and Applied Sciences, Cukurova University, Balcali, Adana, Turkey

4. Private Dental Practice, Motto Oral and Dental Health Polyclinic, Antalya, Turkey

Abstract

Aim: To evaluate the effect of ceramic firing cycles on the internal and marginal discrepancy of restorations fabricated using conventional lost wax casting (LW), direct metal laser sintering (DMLS), and milling for soft metal (MS). Materials and Methods: A total of 45 restorations were produced by LW, DMLS, and MS methods ( n = 15), according to the digital impression on the metal die representing the prepared first molar. The internal discrepancy (ID) was measured through the silicon weight method and the marginal discrepancy (MD) was measured using a light microscope. ID and MD measurements were repeated following the metal manufacturing, ceramic application, and glazing. Statistical analyses were conducted by means of two-way analysis of variance and Tukey-HSD ( α = 0.05) tests. Results: Statistically significant differences were found between the fabrication methods ( P ≤ 0.001) both for MD and ID. The mean MD values of the restorations were 31.4 ± 13.8 µm for MS, 20.8 ± 14.4 µm for LW, and 7.3 ± 6 µm for DMLS. A statistically significant increase was observed in the mean MD values of metal frameworks ( P ≤ 0.001) following ceramic and glaze applications. However, no statistically significant difference was found between the ceramic and the glaze applied stages ( P = .072). The mean ID values were 37 ± 5.7 mg for LW, 28 ± 6.1 mg for DMLS, and 21.6 ± 7.3 mg for MS. Unlike the manufacturing method, ceramic firing cycles had no effects on the ID ( P > 0.05). Conclusion: MS had the highest mean MD, but it had the lowest ID. The ceramic firing had a significantly negative effect only on MD.

Publisher

SAGE Publications

Subject

Pharmacology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3