Auditory Brainstem and Middle Latency Responses

Author:

Kavanagh Kevin T.1,Harker Lee A.2,Tyler Richard S.2

Affiliation:

1. Memphis, Tennessee

2. Iowa City, Iowa

Abstract

Auditory brainstem (ABR) and middle latency responses (MLR) were recorded for ten normal subjects. Changes in wave latency were recorded with high- and low-pass filtering using Butterworth filters with standard phase-shift characteristics. When an open filter (15–3,000 Hz) was used, waves IV, V and VI of the ABR were superimposed on wave Pø of the MLR. A positive (P) wave was recorded in the trough of wave Na as the high-frequency cutoff of the recording bandpass (15–100 Hz) was raised above 100 Hz. Wave P divided Na into two parts. The first trough was the slow-negative response and the second was Na2. The origin of the P wave is unclear but may represent a muscle potential. Because of previous inconsistencies in the waveform identification used with these recording techniques, the authors present a modified method of classification which accommodates changes in waveform appearance that occur with different response filtering. The thresholds for various waves of the auditory brainstem (ABR) or middle latency response (MLR) were determined to a 500-Hz tone pip in ten normal listeners in a variety of recording filter bandwidths. Wave V (recording filters 100–3,000 Hz) had a threhsold of 26 dB nHL. Wave SN (30–3,000 Hz) had a threshold of 18 dB nHL. Waves Na, Pa and Nb had thresholds of 10 to 11 dB nHL. The threshold for waves Na, Pa and Nb were unaffected by changing the recording bandpass from 15–100 Hz to 15–3,000 Hz. The ABR amplitude increased when the recording filter's low-frequency cutoff was lowered from 100 to 15 Hz (high frequency cutoff, 3,000 Hz). This augmentation is probably due to the inclusion of the lower frequency energy of wave Pø. Lowering the recording filters high-frequency cutoff from 3,000 to 100 Hz (low-frequency cutoff, 15 Hz) resulted in exclusion of the higher frequency ABR but did not elevate response threshold. In all listeners tested, the MLR had a lower threshold than the ABR to a 500-Hz tone pip. It is suggested that the MLR has good potential for use in evaluation of low-frequency threshold.

Publisher

SAGE Publications

Subject

General Medicine,Otorhinolaryngology

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3