A Non-inferiority Trial: Safety and Efficacy of Topical 1:1000 versus 1:10 000 Epinephrine in Sino-nasal Surgeries

Author:

Dow Cassie L.123ORCID,Sideris Anders W.123,Singh Ravjit123,Giles Mitchell H.2,Banks Catherine12,Meller Catherine12,Choroomi Sim123,Havas Thomas E.123

Affiliation:

1. Otorhinolaryngology Head and Neck Research Group, Prince of Wales Hospital, Randwick, NSW, Australia

2. Otolaryngology – Head and Neck Surgery Department, Prince of Wales Hospital, Randwick, NSW, Australia

3. Prince of Wales Clinical School, Faculty of Medicine, University of New South Wales, Kensington, NSW, Australia

Abstract

Objective: This study aimed to test the non-inferiority of topical 1:1000 epinephrine compared to topical 1:10 000 with regard to intraoperative hemodynamic stability, and to determine whether it produced superior visibility conditions. Methods: A single-blinded, prospective, cross-over non-inferiority trial was performed. Topical 1:1000 or topical 1:10 000 was placed in 1 nasal passage. Hemodynamic parameters (heart rate, systolic and diastolic blood pressures, and mean arterial pressure) were measured prior to insertion then every minute for 10 minutes. This was repeated in the contralateral nasal passage of the same patient with the alternate concentration. The surgeon graded the visualization of each passage using the Boezaart Scale. The medians of the greatest absolute change in parameters were compared using a Wilcoxon Rank-Signed test and confidence intervals were calculated using a Hodges-Lehman test. The non-inferiority margin was pre-determined at 10 bpm for heart rate and 10 mmHg for blood pressures. A Wilcoxon Rank-Signed test was used to assess superiority in visualization. Results: Thirty-two patients were enrolled and after exclusions, nineteen were assessed (mean age = 35.63 ± 12.49). Differences in means of greatest absolute change between the 2 concentrations were calculated (heart rate = 2.49 ± 1.20; systolic = −1.51 ± 2.16; diastolic = 2.47 ± 1.47; mean arterial pressure = 0.07 ± 1.83). In analyses of medians, 1:1000 was non-inferior to the 1:10 000. There was a significant difference (–0.58 ± 0.84; P = .012) in visualization in favor of topical 1:1000. Conclusion: Topical 1:1000 epinephrine provides no worse intraoperative hemodynamic stability compared to topical 1:10 000 but affords superior visualization and should be used to optimize surgical conditions.

Publisher

SAGE Publications

Subject

General Medicine,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3