Author:
Dunn Camille C.,Tyler Richard S.,Witt Shelley A.,Gantz Bruce J.
Abstract
Objectives: Three different Advanced Bionics processing strategies were evaluated: 1) 8-channel, 813 pulses per second (pps), Continuous Interleaved Sampling (CIS); 2) 16-channel, 5,100 pps, HiResolution Paired (HiRes P); and 3) 16-channel, 2,900 pps, HiResolution Sequential (HiRes S). Methods: Seven adult bilateral Clarion CII cochlear implant recipients who had been using a CIS processing strategy for at least 18 months participated in this study. Sentence recognition in multitalker babble from the front was collected on subjects using their CIS strategy and after subjects were programmed for the first time with HiRes P and HiRes S strategies. An ABAB design was implemented for 1 month whereby subjects used each HiResolution strategy every other day. Sentence recognition testing was repeated at the 1- and 3-month post-HiResolution test intervals. Results: Comparisons between the CIS and HiResolution strategies showed immediate improvements for 5 subjects in favor of the HiResolution strategies. After 1 month of alternating between the HiRes P and HiRes S strategies, remarkably, 2 subjects showed improvements of 60%, 2 subjects showed improvements of 40%, and 2 subjects showed improvements of 30% over the CIS strategy that they had previously used for at least 18 months. The results after 3 months of use were consistent with those obtained at 1 month. Conclusions: The HiRes S and HiRes P strategies resulted in dramatic improvements in speech perception in noise for a subset of subjects who had been using the CIS strategy bilaterally. This finding demonstrates that these subjects were able to tolerate a more difficult signal-to-noise ratio. Further work is needed to determine the independent effects of rate versus number of channels.
Subject
General Medicine,Otorhinolaryngology
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献