Abstract
The purpose of this study was to investigate the effect of systematic variations in stimulation rate and number of channels on speech understanding in 13 patients with cochlear implants who used the continuous interleaved sampling speech coding strategy. Reducing the stimulation rate from 1,515 to 1,730 pulses per second per channel to 600 pulses per second per channel resulted in decreased overall performance; the understanding of monosyllables and consonants was more affected than the understanding of vowels. Reducing the number of active channels below 7 or 8 channels decreased speech understanding; the identification of vowels and monosyllables was most affected. We conclude that vowel recognition with the continuous interleaved sampling strategy relies on spectral cues more than on temporal cues, increasing with the number of active channels, whereas consonant recognition is more dependent on temporal cues and stimulation rate.
Subject
General Medicine,Otorhinolaryngology
Cited by
62 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献