Objectives: Define and compare the thermal nerve injury caused by 3 different vessel sealing and dissection devices: the harmonic scalpel (HS), the electrothermal bipolar vessel sealing system (EBVS), and the bipolar electrosurgery unit (BE). Methods: First we recorded the heating variations in pig tissue caused by a BE unit, HS, and EBVS after an activation for 5, 10, and 15 seconds at minimum and at maximum power. In the second part, we evaluated the histological damage caused by HS and EBVS on 20 in vivo human nerves, 10 per device. The 2 scalpels were placed and activated at 3 different distances from the nerve (1, 3, and 5 mm). The extension and the degree of the nerve lesion was then calculated. Results: The instrument determining the highest rise in temperature was the BE unit, followed by HS and then EBVS. Comparison between the extension and degree of nerve injury caused by the 2 scalpels showed no statistically significant differences. Based on these evaluations, we established a relative safety limit at 3 mm and an absolute safety limit at 5 mm for both scalpels. Conclusions: Our data suggest EBVS and HS can be considered valid and safe devices for ENT surgery.

Publisher

SAGE Publications

Subject

General Medicine,Otorhinolaryngology

Reference18 articles.

1. Hemostasia y tecnología. Energía. Desarrollo de las nuevas tecnologías

2. Targarona EM, Cerdàn G, Gracia E, Rodríguez M, Trías M. Bisturí ultrasónico. Capítulo III. E.3. Terapéutica mínimamente invasiva y nuevas tecnologías en cirugía general y digestiva. Barcelona: Masson. 2003;343-347.

3. Electrosurgery: History, Principles, and Current and Future Uses

4. Electrosurgery in Otolaryngology???Head and Neck Surgery: Principles, Advances, and Complications

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3