Abstract
Both dynamic viscosity (n′) and elasticity (G′) of middle ear effusion were measured with an oscillating sphere magnetic rheometer and compared with the degree of conductive hearing loss in 65 ears of 40 children. There was a significant correlation between n′ and the magnitude of the air-bone gap at 500 and 1,000 Hz, but there was no significant correlation between G′ and the magnitude of the air-bone gap at 2,000 or 4,000 Hz. No significant correlation was noted between G′ and the magnitude of the air-bone gap at 500,1,000, 2,000, or 4,000 Hz. These results indicate that the n′ of middle ear effusion has an effect on the amount of hearing impairment at frequencies below 1,000 Hz.
Subject
General Medicine,Otorhinolaryngology
Cited by
32 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献