Utility of dual energy CT in differentiating clot in acute ischemic stroke

Author:

Panyaping Theeraphol1ORCID,Udomkaewkanjana Nuchsarang1,Keandoungchun Jesada2

Affiliation:

1. Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand

2. Division of Neurology, Department of Medicine, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand

Abstract

Purpose Red blood cells (RBC)-poor thrombi in acute ischemic stroke (AIS) are associated with longer recanalization time for mechanical thrombectomy than RBC-rich thrombi. The purpose of the study was to differentiate between RBC-rich and RBC-poor thrombi using dual energy computed tomography (DECT). Materials and methods This retrospective study was conducted on patients with acute arterial occlusion of anterior circulation who underwent DECT cerebral angiography, followed by mechanical thrombectomy with the pathological diagnosis of thrombi, dividing into RBC-rich and RBC-poor thrombi. The CT attenuation values and thrombus enhancement were measured in non-contrast scans and CTA phases at different energy levels and compared between RBC-rich and RBC-poor groups. Results Fourteen acute stroke patients were included in the study. There were 7 patients in RBC-rich group and 7 patients in RBC-poor group. The CT attenuation values of RBC-rich thrombi were significantly higher than those of RBC-poor thrombi at energy levels of 40, 50, 60, 70, and 80 KeV, with the most significant difference at 80 KeV ( p = 0.032). A cutoff value of 44.1 Hounsfield units (HU) on 80 keV monoenergetic reconstructions was used to distinguish between RBC-rich and RBC-poor thrombi. It achieved an area under the curve (AUC) of 0.878, sensitivity of 85.7%, specificity of 100%, and accuracy of 92.9%. The degree of enhancement was higher in RBC-poor thrombi than in RBC-rich thrombi, without statistically significant difference. Conclusion DECT could help differentiate between RBC-rich and RBC-poor thrombi by using CT attenuation values in non-contrast phase at lower energy levels (40–80 KeV).

Publisher

SAGE Publications

Subject

Neurology (clinical),Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3