Optimal guiding catheter position during advancement of the guiding catheter into the carotid artery from the aortic arch via transfemoral approach

Author:

Ryu Bikei123ORCID,Mochizuki Tatsuki2,Kushi Kazuki2,Ishikawa Tomomi23,Shima Shogo2ORCID,Sato Shinske123ORCID,Inoue Tatsuya2,Kawamata Takakazu3,Niimi Yasunari1

Affiliation:

1. Department of Neuroendovascular Therapy, St Luke’s International Hospital, Chuo-ku, Japan

2. Department of Neurosurgery, St Luke’s International Hospital, Chuo-ku, Japan

3. Department of Neurosurgery, Tokyo Women’s Medical University, Shinjuku-ku, Japan

Abstract

Background Guiding catheter (GC) advancement into the target carotid artery is a crucial step in neuroendovascular therapy. In difficult anatomies, alternative methods have been reported to overcome difficult carotid access for swift GC advancement. However, studies focusing on the positional relationship between the GC and inner catheter (IC) at the aortic arch are lacking. Methods We evaluated the impact of the positional relationship between the GC and IC on whether the GC position affects catheter support or system straightening. We retrospectively reviewed 89 patients who underwent neuroendovascular therapy. We assessed the time to carotid access across difficult arch anatomies. The GC position was divided into Position 1, descending aorta level; Position 2, aortic arch level; and Position 3, origin of the left common carotid artery or innominate artery. We also evaluated the GC support and straightening effects in an in vitro vascular model study. Results The coaxial catheter flexion angle at the aortic arch was significantly larger when the GC was set to Position 3 ( p < 0.0001). A significantly shorter time to carotid access was observed with Positions 2 and 3 than with Position 1 in the difficult arch anatomy group. In the in vitro vascular model evaluation, the catheter support effect significantly increased as the GC position became closer to the IC tip ( p < 0.0001) and straightening effect significantly increased as the GC moved to Position 2 from Position 1 ( p < 0.0001). Conclusion During GC advancement, the GC positional relationship changed the support of the coaxial system with system straightening. The optimal GC position, Position 3, facilitated swift GC advancement.

Publisher

SAGE Publications

Subject

Neurology (clinical),Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3