Prospective comparison of volumetric post-contrast T1-Sampling Perfection with Application optimized Contrasts by using different flip angle Evolutions and Magnetization-Prepared Rapid Acquisition with Gradient Echo in patients with metastatic melanoma

Author:

Lasocki Arian123ORCID,Caspersz Lauren1,McArthur Grant A24

Affiliation:

1. Department of Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia

2. Sir Peter MacCallum Department of Oncology, The University of Melbourne, Parkville, VIC, Australia

3. Department of Radiology, The University of Melbourne, Parkville, VIC, Australia

4. Department of Medical Oncology, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia

Abstract

Introduction Volumetric turbo spin echo (3D-TSE) T1-weighted imaging techniques such as T1-SPACE (Sampling Perfection with Application optimized Contrasts by using different flip angle Evolutions) improve detection of intracranial metastases (IM) compared to volumetric magnetisation-prepared gradient recalled echo techniques such as MPRAGE (Magnetization-Prepared Rapid Acquisition with Gradient Echo). However, incomplete vascular suppression can produce false positives when using 3D-TSE. Research into 3D-TSE has generally targeted patients with known or suspected IM, but the clinical implications of false positives are greater in patients with lower likelihood of IM. This study examined additional findings identified by T1-SPACE in patients with metastatic melanoma, targeting patients with a lower incidence of IM. Methods Patients with metastatic melanoma and an upcoming brain MRI booking were identified prospectively. Consent for adding post-contrast T1-SPACE to the MRI protocol (which included MPRAGE) was obtained. Imaging was initially assessed without T1-SPACE. Subsequently, T1-SPACE images were examined and additional findings identified were recorded, including their correlation with MPRAGE. Results One hundred examinations were performed, 24 having evidence of active IM. T1-SPACE allowed identification of additional lesions in five patients, including two with small solitary IM not identified when first assessing MPRAGE. In 18 examinations, T1-SPACE identified additional equivocal findings, confidently attributed to artefact (most commonly normal vessels) following correlation with MPRAGE. Conclusion T1-SPACE improves detection of small lesions in patients without known IM, changing patient management. False positives are common but can be clarified with MPRAGE. Combining T1-SPACE and MPRAGE allows both sensitivity and specificity to be optimised.

Funder

Peter MacCallum Cancer Foundation

Publisher

SAGE Publications

Subject

Neurology (clinical),Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3