Safety and efficacy of Surpass Evolve Flow diverter for intracranial aneurysms: A study of 116 patients

Author:

Bibi Richard1,Bankole Nourou Dine Adeniran12ORCID,Donnard Baptiste1,Giubbolini Francesca1,Boucherit Julien13,Barrot Valère1,Herbreteau Denis1,Ifergan Héloïse1,Janot Kevin1,Boulouis Grégoire12,Bala Fouzi1ORCID

Affiliation:

1. Diagnostic and Interventional Neuroradiology Department, University Hospital of Tours, Tours, France

2. Clinical Investigation Center (CIC), INSERM, University Hospital of Tours, Tours, France

3. Department of Neuroradiology, Rennes University Hospital, Rennes, France

Abstract

Background and purpose Flow diverter embolization is a recognized method for treating intracranial aneurysms. This study evaluates the safety and efficacy of the Surpass Evolve flow diverter in treating intracranial aneurysm. Material and methods From May 2019 to June 2022, our center prospectively enrolled patients presenting with both ruptured and unruptured intracranial aneurysms. We assessed aneurysm occlusion, along with the occurrence of ischemic and hemorrhagic complications, and mortality at 6-months. The 3-month occlusion rate was determined using MR angiography, while the 6-month occlusion rate employed the O’Kelly–Marotta (OKM) grading scale on DSA. Results A total of 116 patients with 120 aneurysms received treatment with the Surpass Evolve device. The average aneurysm size was 6.6 mm (range: 2-30 mm). All patients were administered two loading doses of ticagrelor (180 mg) one day before the procedure and 2 h pre-embolization. A procedural complication occurred in one case, involving wire-related perforation of an M3 branch distant from the giant aneurysm; however, this evolved favorably. There were no reported deaths linked to the treatment. Permanent neurological deficits were observed in 3 (2.5%) patients, primarily due to early in-stent thrombosis. MR angiography results at 3 months indicated complete occlusion for 87 out of 115 (75.6%) monitored aneurysms. The 6-month DSA showed neck remnant or complete occlusion (OKM grade C or D) in 86 out of the 107 (80.4%) patients who underwent follow-up. Conclusion The Surpass Evolve stands out as a reliable and effective flow diverter for the management of intracranial aneurysms.

Publisher

SAGE Publications

Subject

Neurology (clinical),Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3