Abstract

Objectives To assess the diagnostic accuracy and lesion conspicuity of susceptibility-weighted angiography (SWAN) and T2* for the clot detection in acute cerebral venous thrombosis (CVT) by comparison with contrast-enhanced MR venography. Methods Venous thrombi detection and conspicuity were assessed by two readers for 18 venous segments on both T2*, SWAN source images, 2D SWAN reformats matching with T2*, and 3D SWAN images (SWAN-MinIP). Images obtained with the three reading techniques were systematically scored and compared to CE MRV findings, in a blinded fashion, per patient and per segment, and compared to each other. Results In 30 patients, 137 thrombosed venous segments were evaluated. The sensitivity of T2*, SWAN source images, 2D SWAN, and SWAN MinIP were, respectively, of 89.3%/82.1%, 82.1%, and 82.1% for dural sinus thrombosis and of 100%/100%/100%/96.6% for cortical venous thrombosis. There were significant differences in thrombus detection between T2* and SWAN: T2* versus SWAN source images and 2D SWAN ( p = 0.04) and versus SWAN MinIP ( p = 0.03). There were no significant differences between the three modalities of SWAN images. T2* was more sensitive than all SWAN images for both sigmoid sinus thrombosis and intracranial internal jugular vein thrombosis ( p = 0.04). Inter-observer agreement was slightly superior with T2* ( p < 0.05). Conclusion In this small cohort, SWAN sequence at 3T did not yield additional value for thrombus detection in acute CVT compared to T2*. This study highlights SWAN’s greatest weakness both for diagnostic accuracy and lesion conspicuity compared to T2* for acute venous clot detection near the skull base.

Publisher

SAGE Publications

Subject

Neurology (clinical),Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3