The sensitivity of MIPs of 3D contrast-enhanced VIBE T1-weighted imaging for the detection of small brain metastases (≤ 5 mm) on 1.5 tesla MRI

Author:

Parillo Marco12ORCID,Vertulli Daniele12,Vaccarino Federica12,Mallio Carlo Augusto12,Beomonte Zobel Bruno12,Quattrocchi Carlo Cosimo3

Affiliation:

1. Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, Rome, Italy

2. Research Unit of Diagnostic Imaging and Interventional Radiology, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, Rome, Italy

3. Centre for Medical Sciences-CISMed, University of Trento, Italy

Abstract

Objectives To evaluate whether the use of Maximum Intensity Projection (MIP) images derived from contrast-enhanced 3D-T1-weighted volumetric interpolated breath-hold examination (VIBE) would allow more sensitive detection of small (≤5 mm) brain metastases (BM) compared with source as well as 2D-T1-weighted spin-echo (SE) images. Methods We performed a single center retrospective study on subjects with BM who underwent 1.5 tesla brain magnetic resonance imaging. Two readers counted the number of small BM for each of the seven sets of contrast-enhanced images created: axial 2D-T1-weighted SE, 3D-T1-weighted VIBE, 2.5 mm-thick-MIP T1-weighted VIBE, and 5 mm-thick-MIP T1-weighted VIBE; sagittal 3D-T1-weighted VIBE, 2.5 mm-thick-MIP T1-weighted VIBE, and 5 mm-thick-MIP T1-weighted VIBE. Total number of lesions detected on each image type was compared. Sensitivity, the average rates of false negatives and false positives, and the mean discrepancy were evaluated. Results A total of 403 small BM were identified in 49 patients. Significant differences were found: in the number of true positives and false negatives between the axial 2D-T1-weighted SE sequence and all other imaging techniques; in the number of false positives between the axial 2D-T1-weighted SE and the axial 3D-T1-weighted VIBE sequences. The two image types that combined offered the highest sensitivity were 2D-T1-weighted SE and axial 2.5 mm-thick-MIP T1-weighted VIBE. The axial 2D-T1-weighted SE sequence differed significantly in sensitivity from all other sequences. Conclusion MIP images did not show a significant difference in sensitivity for the detection of small BM compared with native images.

Publisher

SAGE Publications

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3