Angioplasty and Stenting of Symptomatic Vertebral Artery Stenosis Clinical and Angiographic Follow-up of 206 Cases from Northwest Iran

Author:

Mohammadian R.1,Sharifipour E.1,Mansourizadeh R.2,Sohrabi B.3,Nayebi A.R.2,Haririan S.2,Farhoudi M.1,Charsouei S.1,Najmi S.1

Affiliation:

1. Neuroscience Research Center, Tabriz University of Medical Sciences; Tabriz, Iran

2. Neurology Department, Alinasab Hospital; Tabriz, Iran

3. Cardiovascular Research Center, Tabriz University of Medical Sciences; Tabriz, Iran

Abstract

Percutaneous transluminal angioplasty (PTA) has recently become a noteworthy treatment option for significant stenosis involving the vertebral artery (VA) in selected patients. We conducted a prospective study to evaluate the efficacy, safety and mid-term follow up results of 206 cases received PTA with or without stent implant to treat their symptomatic atherosclerotic VA stenosis in all segments (V1-V4). In a prospective mono-arm trial from October 2008 to July 2012 in a single center, 239 lesions affecting the intra or extracranial VA (171 in V1, 17 in V2, 14 in V3, 21 in V4 and 16 in combined segments) were treated by PTA with or without stent implant. Non-disabling stroke patients who had failed conservative medical treatment and had angiographic evidence of >50% stenosis in the dominant VA with clinical signs and symptoms of VB stenosis were included in this study. They were mean followed for 13.15±5.24 months after treatment. Overall, 206 patients underwent the procedure. A stent was implemented in 199 patients (96.6%). The periprocedural complication rate was 7.2%. The procedural (technical) success rate was 97.6%. Of the total 239 lesions, 223 were treated with stent implant. Clinical success was achieved in all 206 symptomatic patients after the procedure. Restenosis occurred in 15.9% after a mean 10.8 (6–24) months. Of those, 63.1% and 34.2% had mild and moderate stenosis that was treated medically, whereas one case (2.6%) with severe restenosis underwent balloon angioplasty. No deaths occurred during the follow-up period. The follow-up complication rate was 6.3%. TIA occurred in 4.4%, a minor stroke in 1.4% and a major stroke in one patient. The overall patient event-free survival was 92.4%. These results demonstrate the safety and feasibility of PTA with or without stent implant, with a high technical success rate, a low complication rate, a low restenosis rate and durable clinical success in patients with symptomatic VA stenosis. This approach seems to improve patients' immediate and mid-term clinical results. Randomized controlled trials are necessary to further validate this treatment option.

Publisher

SAGE Publications

Subject

Clinical Neurology,Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3