Pseudo-continuous arterial spin labeling with short post-labeling delay time sensitively reflects the hemodynamics of symptomatic patients with permanent large vessel occlusion before and after revascularization

Author:

Mizowaki Takashi1ORCID,Hosoda Kohkichi2,Inoue Satoshi1,Kuroda Ryuichi1,Kurihara Eiji1

Affiliation:

1. Department of Neurosurgery, Junshin Hospital, Kakogawa, Japan

2. Department of Neurosurgery, Kobe City Nishi-Kobe Medical Center, Kobe, Japan

Abstract

Background and Purpose This study evaluated the feasibility of arterial spin labeling (ASL) for diagnosing hemodynamic stroke due to permanent anterior circulation large vessel occlusion. Methods Three-dimensional pseudo-continuous ASL data at two post-labeling delay (PLD) times (1.5 and 2.5 s) in patients with unilateral permanent middle cerebral artery (MCA) segment 1 (M1) or internal cerebral artery (ICA) occlusion were acquired during routine magnetic resonance angiography. Sixty-one patients with symptomatic occlusion (M1, 24; ICA, 37) and 69 patients with asymptomatic occlusion (M1, 21; ICA, 48) were enrolled. Regions of interest were automatically placed in the MCA region using a template. The respective scans were compared with asymptomatic M1 or ICA occlusion scans. The ratio of signal intensity (occlusion side/non-occlusion side) in the perfusion area of MCA (asymmetry index [AI]) was compared between both groups. Results In both PLD groups, AI was significantly lower in symptomatic patients than in asymptomatic patients. The receiver operating characteristic curve showed moderate capacity for the prediction of symptomatic AI in both groups (area under the curve, 0.739 and 0.712, respectively). As a result of extracranial-intracranial bypass operation in 28 symptomatic (M1, eight; ICA, 20) patients, AI was significantly higher postoperatively in the PLD 1.5 s group than in the PLD 2.5 s group. Conclusion In symptomatic patients with permanent large vessel occlusion, the signal intensity ratio of pseudo-continuous ASL with short PLD sensitively reflects the hemodynamics before and after revascularization; therefore, this technique may be an alternative method in situations where PET or SPECT cannot be performed.

Publisher

SAGE Publications

Subject

Neurology (clinical),Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3