Mechanical characterization of hydrolysis effects on the stiffness of bioabsorbable polymeric filaments: An experimental and modeling approach based on a simple constitutive damage model

Author:

Carniel Thiago André1ORCID,de Castro Paulo Bastos2ORCID,Santos André Luiz Grando1,de Mello Roesler Carlos Rodrigo23,Breitenbach Everton Rafael1,Salmoria Gean Vitor23,Morozo Mário Augusto1,Colaço Pablo Antônio1,Fiori Márcio Antônio145,Fancello Eduardo Alberto23

Affiliation:

1. Area of Exact and Environmental Sciences, Community University of Chapecó Region, Chapecó, Santa Catarina, Brazil

2. Department of Mechanical Engineering, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil

3. Biomechanical Engineering Laboratory, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil

4. Post-Graduate Program in Technology and Management of the Innovation, Community University of Chapecó Region, Chapecó, Santa Catarina, Brazil

5. Post-Graduate Program in Environmental Science, Community University of Chapecó Region, Chapecó, Santa Catarina, Brazil

Abstract

This manuscript presents an experimental and modeling approach in order to characterize the stiffness loss of bioabsorbable polymer filaments due to hydrolysis. In this regard, bioabsorbable suture yarns (poly(lactic-co-glycolic) acid—PLGA) were chosen as a representative material for the present investigation. The observed mechanical response was characterized by means of a thermodynamically consistent constitutive variational framework. Usually, two different damage variables are assumed to take place in this class of materials: a hydrolytic damage (long-term degradation) and a strain-driven damage (short-term degradation). This work concerns the proposition of a constitutive model that only considers the hydrolytic damage, in which a specific strain energy and a proper dissipation damage potential were tailored to model the tested material. A nonlinear curve fitting procedure based on Particle Swarm Optimization was performed to identify the constitutive parameters. A set of numerical simulations demonstrates the effectiveness of the proposed constitutive model to predict damage-induced creep and damage-induced stress relaxation, behaviors that can be used as design criteria in absorbable implants. The main achieved results show that the proposed constitutive approach leads to a simple but effective model capable to drive the first steps in the design of absorbable biomedical devices. The present variational framework can be extended to study the constitutive response of other bioabsorbable polymers, accounting for viscous and/or plastic behaviors.

Publisher

SAGE Publications

Subject

Materials Chemistry,Polymers and Plastics,Ceramics and Composites

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献