Reliability of Automated Blood Pressure Devices used by Hypertensive Patients

Author:

Wong William C W1,Shiu Ivan K L2,Hwong Thomas M T3,Dickinson James A4

Affiliation:

1. Department of Community and Family Medicine, 4th Floor, School of Public Health, Prince of Wales Hospital, Chinese University of Hong Kong, Shatin, New Territories, Hong Kong

2. Lek Yuen Medical Centre, Shatin

3. Cardiothoracic Unit, Prince of Wales Hospital, Shatin

4. Family Medicine, University of Calgary, UCMC North Hill 1707, Alberta-Calgary T2N 1M7, Canada

Abstract

Automated blood pressure (BP) devices are used by many hypertensive patients in Hong Kong, with or without medical advice. At two community clinics, we invited hypertensive patients aged between 40 and 70 years who used such a device to fill in a questionnaire and to have four sets of BP measurements, automated and mercury, at two visits. Of 290 hypertensive patients 120 fulfilled the criteria, and 73 of these agreed to participate. 53 devices measured arm BP, 21 measured forearm BP. The agreement between the mercury sphygmomanometer and the automated devices was poor, with average differences of 9.5 mmHg for systolic and 9.4 mmHg for diastolic and no clear advantage for either site of measurement. As a means of screening for BP >140/90 mmHg the sensitivity of the automated devices was 81% and the specificity was 80%. There were large variations in how often and under what circumstances the devices had been used. One-fifth of the devices had been acquired on medical advice but only 11% of the participants were aware of the three important conditions for operating such devices. Discussion of automated devices, their role and proper use, should now be part of routine hypertensive care.

Publisher

SAGE Publications

Subject

General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. The reliability of patient blood pressure self-assessments – a cross-sectional study;BMC Primary Care;2023-01-03

2. Proposal of a method for the evaluation of inaccuracy of home sphygmomanometers;Blood Pressure Monitoring;2009-10

3. Home sphygmomanometers: validation versus accuracy;Blood Pressure Monitoring;2009-02

4. PHYSICAL EXAMINATION PROCEDURES;Clinical Procedures in Primary Eye Care;2007

5. Goodbye Mercury? Blood Pressure Measurement and Its Future;Journal of the Royal Society of Medicine;2005-03