Author:
Levesque Katherine A.,Johnson Cary E.
Abstract
The objective of this project was to determine the incidence, location, and potential transmission of bacteria from pressurized inhalers contaminated during normal use by pediatric patients. Patients' inhaler usage and cleaning patterns also were evaluated. Fifteen inhalers from 12 children were cultured at three separate sites: the mouthpiece, spray portal, and the spray itself. The patient and/or parent were interviewed to determine usage and cleaning patterns. No bacterial growth was found from any of the cultured sites or aerosol of the control inhalers. All of the mouthpieces and portals of the patient-used inhalers were positive for growth, which is significant (p < 0.01). One patient-used inhaler was positive for bacterial growth from the aerosol, which is not significant (p > 0.05). These results demonstrate that despite inhaler contamination, bacteria are not significantly transmitted by the aerosol. Routine cleaning of inhalers to remove accumulated debris is recommended to prevent disruption of drug delivery.
Subject
Pharmacology (medical),General Pharmacology, Toxicology and Pharmaceutics
Cited by
5 articles.
订阅此论文施引文献