Accuracy of 4 Free Online Dosing Calculators in Predicting the Vancomycin Area Under the Concentration-Time Curve Calculated Using a 2-Point Pharmacokinetic Approach

Author:

Belz Sarah N.1,Seabury Robert W.23,Steele Jeffrey M.23,Darko William23,Miller Christopher D.23,Probst Luke A.23,Kufel Wesley D.234ORCID

Affiliation:

1. Children’s National Hospital, Washington, DC, USA

2. State University of New York Upstate University Hospital, Syracuse, NY, USA

3. State University of New York Upstate Medical University, Syracuse, NY, USA

4. Binghamton University School of Pharmacy and Pharmaceutical Sciences, Binghamton, NY, USA

Abstract

Background: Free online adaptive vancomycin dosing calculators are available to estimate area under the concentration-time curve (AUC), but the accuracy of predicting vancomycin AUC using these calculators compared with using a 2-point pharmacokinetic approach has not been described. Objective: To evaluate the accuracy of calculator-predicted AUC (cpAUC) using 4 free online calculators compared with reference AUC (rAUC), and to assess pharmacists’ impressions of the ease of use. Methods: Vancomycin AUC was estimated using (1) the reference method via the Sawchuk-Zaske method and linear-logarithmic trapezoidal rule using 2 steady-state postdistributional vancomycin serum concentrations and (2) 4 free online vancomycin dosing calculators including ClinCalc, VancoPK, TDMx, and DMC. Accuracy was calculated by dividing cpAUC by rAUC. Ease of cpAUC estimation was determined by using a 10-point Likert scale. Results: All 4 calculators had a median cpAUC accuracy ranging from 89% to 110%. Concordance between cpAUC and rAUC determinations of AUC <400 and > 600 mg·h/L occurred 63.3% to 71.4% and 74.5% to 78.6% of the time, respectively. Pharmacist investigators agreed that ClinCalc and VancoPK calculators were easiest to use. Conclusion and Relevance: cpAUC accuracy varied among the 4 calculators, but all consistently identified patients with an rAUC <400 mg·h/L and an rAUC > 600 mg·h/L at comparable frequencies. All 4 calculators demonstrated some imprecision based on their wide 95% CIs and potential inaccuracies in predicting an rAUC <400 mg·h/L or an rAUC > 600 mg·h/L. Clin Calc and VancoPK were most user friendly based on our pharmacists’ impressions.

Funder

council on graduate medical education, new york state department of health

Publisher

SAGE Publications

Subject

Pharmacology (medical)