Assessment of Patient Acceptance and Inhalation Technique of a Pressurized Aerosol Inhaler and Two Breath-Actuated Devices

Author:

Nimmo Cindy J. Reesor,Chen Daniel N.M.,Martinusen Shelagh M.,Ustad Tina L.,Ostrow David N.

Abstract

OBJECTIVE: To assess inhalation technique in patients after written instruction alone, written and verbal instruction, and clinical use of two new inhalation devices. DESIGN: Randomized, crossover evaluation of the albuterol Diskhaler and the terbutaline Turbuhaler. SETTING: Canadian tertiary-care hospital. PATIENTS: Twenty hospitalized adults with asthma or chronic obstructive pulmonary disease currently using an albuterol metered-dose inhaler (MDI). Nineteen patients received Diskhaler, 16 received Turbuhaler, 15 received both inhalers, and 10 patients used both inhalers for three days each. INTERVENTIONS: Patients were randomized to receive either Diskhaler or Turbuhaler for three days. Inhaler technique was assessed after written instruction, written plus verbal instruction, at the first scheduled dose after instruction, and after three days of clinical use. Patients remaining in the hospital after three days crossed over to the other study inhaler and the same protocol was followed. MAIN OUTCOME MEASURES: Patient inhalation technique was assessed and compared for the MDI, Diskhaler, and Turbuhaler. RESULTS: Assessment of MDI technique revealed that 35 percent of patients used their MDI correctly on the first puff, and 42 percent used it correctly on the second puff. Following written instruction alone, correct technique was demonstrated by 32 percent of patients with Diskhaler and 6 percent with Turbuhaler. Technique significantly improved following verbal instruction, although 40 percent of the patients required up to three attempts to demonstrate correct technique on at least one of the study inhalers. After three days of clinical use, correct technique was demonstrated in only 54 percent of the Diskhaler and 64 percent of the Turbuhaler assessments. Performance at this assessment was, however, significantly better on the Turbuhaler than on the MDI (p=0.01). Performance on the Diskhaler was not significantly different from the performance on the other inhalers. CONCLUSIONS: Written instruction alone is inadequate in teaching correct inhalation technique. Verbal instruction and technique assessment are essential for patients to achieve proper technique. Patients may perform better on the Turbuhaler than on other inhalation devices.

Publisher

SAGE Publications

Subject

Pharmacology (medical)

Cited by 89 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3