Comparing Anti–Factor Xa and Activated Partial Thromboplastin Levels for Monitoring Unfractionated Heparin

Author:

Wahking Rebekah A.1,Hargreaves Rachel H.2,Lockwood Sean M.2,Haskell Sabrina K.3,Davis Kelly W.2

Affiliation:

1. Cincinnati Veterans Affairs Medical Center, Cincinnati, OH, USA

2. Lexington Veterans Affairs Health Care System, Lexington, KY, USA

3. Milwaukee Veterans Affairs Medical Center, Milwaukee, WI, USA

Abstract

Background: Lab tests such as activated partial thromboplastin time (aPTT) or anti–factor Xa (anti-Xa) levels are typically used to monitor intravenous unfractionated heparin (IV heparin), with recent evidence suggesting that anti-Xa levels may provide a more accurate measure of anticoagulation. Objective: The Lexington Veterans Affairs Health Care System transitioned from using aPTT to anti-Xa levels in January 2017. This study was conducted to evaluate the efficacy and safety of this change. Methods: This was a retrospective cohort study comparing all patients receiving IV heparin per protocol for at least 24 hours from August 1, 2016, to January 31, 2017 (aPTT group), and February 1, 2017, to July 31, 2017 (anti-Xa group). The primary objective was a comparison of IV heparin doses required to achieve goal range between the 2 cohorts. Secondary objectives included a comparison of time to therapeutic goal, percentage of time within goal range, number of rate changes until therapeutic goal, and adverse outcomes, such as number of bleeds. Results: A total of 155 patients were included in this study. Significantly higher IV heparin doses were required to achieve therapeutic goal in the anti-Xa group, despite significantly fewer IV heparin rate changes required. Anti-Xa monitoring was not associated with an increased risk of adverse events. Conclusion and Relevance: Significantly higher IV heparin doses were required to achieve therapeutic anti-Xa levels after transitioning from an aPTT-based protocol in the largely unstudied veteran population. However, the transition from aPTT to anti-Xa monitoring appears safe and efficacious in these patients.

Publisher

SAGE Publications

Subject

Pharmacology (medical)

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3