Stent Angioplasty for Post-Operative Coronary Artery Stenosis in Infants

Author:

Chaszczewski Kasey J.123,Nicholson George T.4,Shahanavaz Shabana5,Dori Yoav3,Gillespie Matthew J.3,O’Byrne Michael L.367,Rome Jonathan J.3,Glatz Andrew C.36

Affiliation:

1. Department of Pediatrics, Medical College of Wisconsin, Milwaukee, WI, USA

2. Section of Pediatric Cardiology, The Herma Heart Institute, Milwaukee, WI, USA

3. Division of Cardiology, The Children’s Hospital of Philadelphia and Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA, USA

4. Division of Pediatric Cardiology, Department of Pediatrics, Vanderbilt University School of Medicine, Nashville, TN, USA

5. The Heart Institute, Cincinnati Children's Hospital Medical Center, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA. Work completed at: Department of Pediatrics, Division of Cardiology, Washington University in St. Louis School of Medicine, St. Louis, MO

6. Center for Pediatric Clinical Effectiveness, The Children's Hospital of Philadelphia, Philadelphia, PA, USA

7. Leonard Davis Institute and Center for Cardiovascular Outcomes, Quality, and Evaluative Research, University of Pennsylvania, Philadelphia, PA, USA

Abstract

Introduction While frequently performed in the adult population, percutaneous coronary artery stent angioplasty (CSA) in infants is rare. CSA in infants is challenging because of limited options in terms of appropriately sized (length and diameter) stents, concern about stenting vessels with significant growth potential and limited data regarding durability of benefit. We report a multicenter case series of infants who underwent CSA. Methods A multicenter, retrospective case series of infants who underwent percutaneous CSA to treat post-operative coronary artery stenoses was performed. Results Six infants from 3 institutions who underwent post-operative CSA were identified. The anatomic diagnoses were d-transposition of the great arteries in 3 cases, anomalous left coronary artery from the pulmonary artery in 2 and supravalvar aortic stenosis in 1. All infants were critically ill at the time of CSA. Diameters of coronary artery stents used ranged from 2.25 to 2.75 mm. There were no procedural complications. All stents were patent immediately after placement and the clinical condition improved or stabilized in all patients. Follow-up angiography was available for 3 patients at 4 to 16 months post-CSA, at which time 67% (2/3) remained patent. Conclusion CSA is a feasible and effective therapy for critically ill infants with post-surgical coronary obstruction. Treatment appears to allow at least short-term reperfusion to facilitate recovery of ventricular function and potential development of collateral circulation when longer-term stent patency is not achieved. Longer-term stent patency and coronary artery health remain unanswered questions.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology and Child Health,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3