Applicability and Durability of Valve-Sparing Tetralogy of Fallot Repair

Author:

Stephens Elizabeth H.1,Wolfe Brian L.2,Talwar Abhinav A.2,Patel Angira2,Camarda Joseph A.2,Eltayeb Osama3,Monge Michael C.3,Forbess Joseph M.4

Affiliation:

1. Department of Cardiovascular Surgery, Mayo Clinic, Rochester, MN, USA

2. Division of Cardiology, Ann & Robert H. Lurie Children’s Hospital of Chicago, USA

3. Division of Cardiovascular-Thoracic Surgery, Ann & Robert H. Lurie Children’s Hospital of Chicago, USA

4. Division of Cardiac Surgery, Department of Surgery, University of Maryland School of Medicine. Children's Heart Program, University of Maryland Medical Center, Baltimore, MD

Abstract

Background: Although valve-sparing repair remains ideal for patients with tetralogy of Fallot, the durability of valve-sparing repair and which patients may have been better served with a transannular patch remain unclear. Methods: Retrospective review was performed of tetralogy of Fallot operations at our institution from January 2008 to December 2018. Standard demographic data were collected, including echocardiographic parameters, operative details, and clinical outcomes. Statistical analysis was performed comparing the transannular patch and valve-sparing repair groups. Results: Sixty-seven patients underwent tetralogy of Fallot repair with a median age of 4.5 (3.2-6.0) months and weight of 5.8 (5.2, 6.7) kg. Seventeen (25%) patients underwent transannular patch repair and 50 (75%) patients underwent valve-sparing repair. There was no difference in age or weight between patients who underwent a transannular patch repair and those who underwent a valve-sparing repair. At last follow-up (median 42 months), there was a trend of a higher peak pulmonary valve/right ventricular outflow tract gradient ( P = .06) in the valve-sparing group, but no difference in the pulmonary valve annulus z-scores. Additionally, the pulmonary valve z-scores in the valve-sparing group decreased from −2.3 ± 1.0 on predischarge echocardiogram of to −1.2 ± 1.6 on last follow-up, with the peak gradient on predischarge 23 (0-37) mm Hg remaining stable on last follow-up at 18 (0-29) mm Hg. There was one reoperation: pulmonary valve replacement six years after a transannular patch. Conclusions: Obtaining a postrepair pulmonary valve z-score of −2 yields satisfactory, stable valve-sparing repair with pulmonary valve growth, acceptable gradients, minimal regurgitation, and high freedom from reintervention during follow-up.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology and Child Health,Surgery

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3