Polytetrafluoroethylene Bicuspid Pulmonary Valve Implantation: Experience With 126 Patients

Author:

Quintessenza James Anthony1,Jacobs Jeffrey Phillip1,Chai Paul Jubeong1,Morell Victor O.2,Lindberg Harald3

Affiliation:

1. Congenital Heart Institute of Florida, All Children’s Hospital and Children’s Hospital of Tampa, University of South Florida College of Medicine, Cardiac Surgical Associates of Florida, Saint Petersburg and Tampa, FL, USA

2. Children’s Hospital of Pittsburg, University of Pittsburg, Pittsburg, PA, USA

3. Rikshospitalet, University of Oslo, Oslo, Norway

Abstract

This article reports our initial experience in 126 consecutive patients treated with placement of a surgically created polytetrafluoroethylene (PTFE) bicuspid pulmonary valve at The Congenital Heart Institute of Florida (CHIF). A bicuspid pulmonary valve is created with PTFE and sutured into the right ventricular outflow tract. PTFE bicuspid pulmonary valves were placed in 126 patients (age: range, 3.1-64.7 years, mean, 17.9 years; weight: range, 14.2-113.6 kg, mean, 55.4 kg). All patients had pulmonary insufficiency, pulmonary stenosis, or both, most commonly after previous repair of tetralogy of Fallot (71 patients). Follow-up was up to 8.3 years (range, 0-8.3 years, mean, 3.34 years). Operative mortality was 1 patient (0.8%). Late mortality was non–valve-related in 3 patients (2.4%). The initial 84 patents in this series received valves constructed from PTFE with 0.6-mm thickness. The next 42 patients received valves constructed from PTFE with 0.1-mm thickness. Six patients of 126 (4.8%) required replacement of the PTFE bicuspid pulmonary valve because of immobile and calcified leaflets. All 6 who required replacement of the PTFE bicuspid pulmonary valve initially received a valve constructed from porous 0.6-mm PTFE material. We currently use nonporous 0.1-mm PTFE, which does not allow cellular in-growth and thickening. Early echocardiographic follow-up of these valve leaflets made with 0.1-mm PTFE has demonstrated improved leaflet mobility and pliability and lower transvalvar gradients. PTFE bicuspid pulmonary valve implantation is safe and effective and demonstrates acceptable performance for the intermediate term. It is anticipated that using thinner 0.1-mm PTFE will improve valve function and durability. Long-term follow-up is necessary to determine the true value of this technique.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology and Child Health,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3