Affiliation:
1. Rutland Regional Medical Center, Rutland, Vt (DJP), University of Pittsburgh, Pittsburgh, Pa (JMD)
Abstract
The organ procurement coordinator commonly must correct and maintain the arterial blood pressure during donor care. This article reviews considerations in the accurate measurement of the blood pressure, causes of hypertension and hypotension, and desirable standards to use in order to provide adequate organ perfusion. Recommendations are presented for treatment of hypotension in a titrated response of intravenous fluids, inotropic support, and vasopressor infusion to maintain the mean arterial pressure above 65 mm Hg. Collaborative interaction between the coordinator and physician consultant remains important throughout management of blood pressure changes during donor care.
Cited by
30 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献