Comparison of Strengths of Mandibular Angle Fractures Following Different Plate Designs: A Human Cadaver Study

Author:

Squier Brendan R.1,Kongsong Wichuda2ORCID,Cofield Stacey S.3,Bignault Samuel1ORCID,Sittitavornwong Somsak1ORCID

Affiliation:

1. Department of Oral Maxillofacial Surgery, UAB School of Dentistry, University of Alabama at Birmingham, Birmingham, AL, USA

2. Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, Bangkok Thailand

3. Department of Biostatistics, Chair School of Public Health Online Education Committee, Chair Recruitment and Retention, Biostatistics Graduate Program Committee, University of Alabama at Birmingham School of Public Health, Birmingham, AL, USA

Abstract

Study Design This institutional cross-sectional study using cadaveric mandibles aimed to measure and compare the strengths of three plating designs utilized in osteosynthesis of mandibular angle fractures. Objective There have been prior studies on angle fracture fixation though few biomechanical studies on human cadaveric specimen. This study aims to directly compare the biomechanical strength of different plating designs to the mandibular angle fracture using a human cadaveric specimen substrate. Methods After receiving an angle osteotomy and either single plate, two plate, or 3D plate fixation, the specimens underwent biomechanical testing using the Instron 5565 mechanical testing unit. The primary outcomes measured were peak load at which permanent deformation started, displacement value at peak load, and load necessary for a specific amount of displacement at 1, 3, 5, and 7 mm. Results There were 15 hemi-mandibles in each group. Based on data analysis of all the specimens, there were no significant differences in the mandibular height, ramus width, mandibular thickness, angle height, and gonial angle between the hemimandibles.. This study demonstrated a statistically significant increased strength performance of the 3D plate over the single plate fixation and the 2-plate over the single plate fixation. The results between 2-plate and 3D plate were in similar values. Conclusions In terms of biomechanical strength, the 3D plate and two plate designs outperform the single plate design to mandibular angle fractures. There are various anatomical and patient specific situations that can aid in selection between them. In the absence of the favorable angle fracture and patient, biomechanical strength to the method of fixation selection needs to be considered.

Funder

National Center for Advancing Translational Sciences

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Oral Surgery,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3