Clinical Accuracy of 3D-Planned Maxillary Positioning Using CAD/CAM-Generated Splints in Combination With Temporary Mandibular Fixation in Bimaxillary Orthognathic Surgery

Author:

Pietzka S.12ORCID,Mascha F.12,Winter K.3,Kämmerer P. W.4,Sakkas A.2,Schramm A.12,Wilde F.12

Affiliation:

1. Department of Oral and Maxillofacial Surgery, University Hospital Ulm, Ulm, Germany

2. Department of Oral and Plastic Maxillofacial Surgery, Military Hospital Ulm, Ulm, Germany

3. Institute of Anatomy, Medical Faculty, University of Leipzig, Leipzig, Germany

4. Department of Cranio-Maxillofacial Surgery, University Medical Centre Mainz, Mainz, Germany

Abstract

Study Design: The aim of this study was to evaluate the accuracy of 3-dimensional (3D)-planned maxillary positioning by using computer-assisted design (CAD)/computer-assisted manufacturing (CAM) splints combined with temporary mandibular fixation in bimaxillary orthognathic surgery. In orthognathic surgery, customized splints work sufficiently well to transfer preoperative planning into the operation site for transverse und sagittal positioning of the maxilla. The vertical positioning is more difficult due to the non-fixed mandibular reference. Therefore, the combined use of CAD/CAM splints and temporary mandibular fixation to the zygomatic region was applied for transferring the 3D-planned maxillary position into the operation site from 2012 until 2015 in our hospital. Objective: In addition to the general accuracy, the precision should therefore be checked especially in the vertical plane compared to axial and sagittal plane. Methods: In this retrospective study, we calculated the deviation of 5 occlusal landmarks of the maxilla in 35 consecutive patients by fusing preoperative 3D planning images and postoperative computed tomography scans after bimaxillary surgery. Results: The overall median deviation of maxillary positioning between plan and surgical result was 0.99 mm. The accuracy of left–right positioning was median 0.96 mm. Anterior–posterior positioning of the maxilla showed a median accuracy of 0.94 mm. Just slightly higher values were determined for the upward–downward positioning (median 1.06 mm). Conclusions: This demonstrates the predictability of maxillary positioning by using CAD/CAM splints in combination with temporary mandibular fixation in all 3 axes.

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Oral Surgery,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3