Concise Matrix Analysis of Point-Based Prostate Targeting for Intensity Modulated Radiation Therapy

Author:

Barbiere Joseph1,Hanley Joseph1,Song Yulin2,Dhawan Atam P.3,Chan Maria F.2

Affiliation:

1. Department of Radiation Oncology Hackensack University Medical Center 30 Prospect Avenue Hackensack, NJ 07601, USA

2. Department of Medical Physics Memorial Sloan-Kettering Cancer Center 1275 York Avenue New York, NY 10021, USA

3. Department of Electrical and Computer Engineering New Jersey Institute of Technology University Heights Newark, NJ 07102, USA

Abstract

Intensity Modulated Radiation Therapy (IMRT) has recently emerged as an effective clinical treatment tool to treat various types of cancers by limiting the external beam dose to the surrounding normal tissue. However, the process of limiting external radiation dose to the tissue surrounding the tumor volume is not a trivial task. Several parameters including tumor volume and inhomogeneity, position and shape of the tumor volume, and the geometrical distribution of the radiation beams directly affect the determination of the external radiation dose. In addition, a major variable in effective delivery of the radiation dose is “set-up error” caused by the changes in patient position. Any changes in the position of the patient affect the geometrical location of the tumor volume and, therefore, need to be accommodated in the delivery of radiation beams during the treatment. This work presents a complete matrix representation required to calculate the three-dimensional rigid body homogeneous transformation matrices corresponding to external beam radiotherapy setup error and subsequent corrections in treatment beam parameters. A new concise orthogonal rotation solution is presented for use with clinical noisy data. Monte Carlo simulations prove the new matrix results are consistently better than the standard inverse solution. The required corrections in beam table, gantry, and collimator angles as function of the planned beam gantry angle are derived. For transformations that include a rotation on the sagittal plane, the required offsets to beam parameters are complex functions of the planned gantry angle but are clearly documented graphically for clinical use. A case study is presented with an error analysis that supports the use of the presented method in a clinical environment. Clinical implementation and evaluation of the presented method with patient data is also included in the paper.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3