Tradeoffs for Assuming Rigid Target Motion in Mlc-Based Real Time Target Tracking Radiotherapy: A Dosimetric and Radiobiological Analysis

Author:

Roland Teboh12,Shi Chengyu12,Liu Yaxi2,Crownover R.3,Mavroidis Panayiotis3,Papanikolaou Nikos12

Affiliation:

1. Department of Radiological Sciences University of Texas Health Science Center, San Antonio, TX, USA

2. Department of Radiation Oncology Cancer Therapy and Research Center San Antonio, TX, USA

3. Department of Medical Radiation Physics, Karolinska Institute and Stockholm University, Sweden

Abstract

We report on our assessment of two types of real time target tracking modalities for lung cancer radiotherapy namely (1) single phase propagation (SPP) where motion compensation assumes a rigid target and (2) multi-phase propagation (MPP) where motion compensation considers a deformable target. In a retrospective study involving 4DCT volumes from six (n=6) previously treated lung cancer patients, four-dimensional treatment plans representative of the delivery scenarios were generated per modality and the corresponding dose distributions were derived. The modalities were then evaluated (a) Dosimetrically for target coverage adequacy and normal tissue sparing by computing the mean GTV dose, relative conformity gradient index (CGI), mean lung dose (MLD) and lung V20; (b) Radiobiologically by calculating the biological effective uniform dose ([Formula: see text]) for the target and organs at risk (OAR) and the complication free tumor control probability ( P+). As a reference for the comparative study, we included a 4D Static modality, which was a conventional approach to account for organ motion and involved the use of individualized motion margins. With reference to the 4D Static modality, the average percent decrease in lung V20 and MLD were respectively (13.1±6.9) % and (11.4±5.6) % for the MPP modality, whereas for the SPP modality they were (9.4±6.2) % and (7.2±4.7) %. On the other hand, the CGI was observed to improve by 15.3±13.2 and 9.6±10.0 points for the MPP and SPP modalities, respectively while the mean GTV dose agreed to better than 3% difference across all the modalities. A similar trend was observed in the radiobiological analysis where the P+ improved on average by (6.7±4.9) % and (4.1±3.6) % for the MPP and SPP modalities, respectively while the [Formula: see text] computed for the OAR decreased on average by (6.2±3.6) % and (3.8±3.5) % for the MPP and SPP tracking modalities, respectively. The [Formula: see text] calculated for the GTV for all the modalities was in agreement to better than 2% difference. In general, respiratory motion induces target displacement and deformation and therefore the complex MPP real time target tracking modality is the preferred. On the other hand, the SPP approach affords simplicity in implementation at the expense of failing to account for target deformation. Radiobiological and dosimetric analyses enabled us to investigate the consequences of failing to compensate for deformation and assess the impact if any on the clinical outcome. While it is not possible to draw any general conclusions on a small patient cohort, our study suggests that the two tracking modalities can lead to comparable clinical outcomes and as expected are advantageous when compared with the static conventional modality.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3