High-Dose Robotic Stereotactic Body Radiotherapy in the Treatment of Patients With Prostate Cancer

Author:

Pontoriero A.1,Iatì G.2,Mondello S.3,Midili F.2,Siragusa C.2,Brogna A.2,Ielo I.2,Anastasi G.2,Magno C.4,Pergolizzi S.1,De Renzis C.1

Affiliation:

1. Department of Biomedical Sciences and Morphological and Functional Images, University of Messina, Messina, Italy

2. A.O.U. “G. Martino”, Operative Unit of Radiation Oncology, Messina, Italy

3. Department of Neuroscience Messina, University of Messina, Messina, Italy

4. Department of General Surgery, Oncology and Pathology, University of Messina, Messina, Italy

Abstract

Background: Stereotactic body radiotherapy (SBRT) can emulate high dose rate brachytherapy (HDR-BRT) dose fractionation. We report our preliminary results using SBRT in monotherapy or pre-external-beam radiotherapy (EBRT) boost in patients with localized prostate cancer (LpC). The primary end point was the evaluation of both acute and late toxicities; secondary end point was the observation of prostate-specific antigen (PSA) nadir. Patients and Methods: Patients with LpC having prostate volume ≤90 cm3 were enrolled in the present study. Patients were treated with SBRT alone or in combined modality (SBRT + EBRT). SBRT was performed using a CyberKnife System (Accuray Incorporated, Sunnyvale, California) and fiducial tracking system. Results: From February 2008 to July 2013, 21 patients for monotherapy (38 Gy/4 fractions) and 5 for combined modality (9.5 Gy/2 fractions plus 46 Gy/23 fractions EBRT) were enrolled. Androgen deprivation therapy (ADT) was administered in 16 of the 26 patients. The median pretreatment PSA was 9.4 (range, 4.5-14.3) ng/mL. All patients completed the planned therapy. Acute Grade 1 toxicity was observed in 18 patients, genitourinary (GU) in 12 / 26 patients, and gastrointestinal (GI) in 6 / 26 patients. Acute Grade 2 GU toxicity was reported in 1 / 26 patients, and Grade 2 GI toxicity was observed in 2 / 26 patients. The median PSA nadir was 0.15 (range, 0.02 = 1.4) ng/mL. Late toxicities were observed in 5 / 26 patients: Grade 1 GU (3 of 26), Grade 2 GU (1 of 26), and Grade 1 GI (1 of 26). Median follow-up was 21.5 (range, 8-65) months. Conclusions: Our preliminary results of SBRT “simulating” HDR for LpC confirm a minimal toxicity and an optimal PSA response. The PSA nadirs appear comparable with HDR-BRT.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3