Helical Tomotherapy as a Means of Delivering Accelerated Partial Breast Irradiation

Author:

Hui Susanta K.1,Das Rupak K.1,Kapatoes Jeff2,Oliviera Gustavo2,Becker Stuart3,Odau Heath3,Fenwick John D.13,Patel Rakesh1,Kuske Robert1,Mehta Minesh1,Paliwal Bhudatt13,Mackie Thomas R.132,Fowler Jack F.1,Welsh James S.1

Affiliation:

1. Department of Human Oncology

2. Tomotherapy Incorporated 1240 Deming Way Madison, WI 53717 USA

3. Department of Medical Physics University of Wisconsin-Madison 600 Highland Avenue Madison WI 53792 USA

Abstract

A novel treatment approach utilizing helical tomotherapy for partial breast irradiation for patients with early-stage breast cancer is described. This technique may serve as an alternative to high dose-rate (HDR) interstitial brachytherapy and standard linac-based approaches. Through helical tomotherapy, highly conformal irradiation of target volumes and avoidance of normal sensitive structures can be achieved. Unlike HDR brachytherapy, it is noninvasive. Unlike other linac-based techniques, it provides image-guided adaptive radiotherapy along with intensity modulation. A treatment planning CT scan was obtained as usual on a post-lumpectomy patient undergoing HDR interstitial breast brachytherapy. The patient underwent catheter placement for HDR treatment and was positioned prone on a specially designed position-supporting mattress during C T. The planning target volume (PTV) was defined as the lumpectomy bed plus a 20 mm margin. The prescription dose was 34 Gy (10 fx of 3.4 Gy) in both the CT based HDR and on the tomotherapy plan. Cumulative dose-volume histograms (DVHs) were generated and analyzed for the target, lung, heart, skin, pectoralis muscle, and chest wall for both HDR brachytherapy and helical tomotherapy. Dosimetric coverage of the target with helical tomotherapy was conformal and homogeneous. “Hot spots” (≥150% isodose line) were present around implanted dwell positions in brachytherapy plan whereas no isodose lines higher than 109% were present in the helical tomotherapy plan. Similar dose coverage was achieved for lung, pectoralis muscle, heart, chest wall and breast skin with the two methods. We also compared our results to that obtained using conventional linac-based three dimensional (3D) conformal accelerated partial breast irradiation. Dose homogeneity is excellent with 3D conformal irradiation, and lung, heart and chest wall dose is less than for either HDR brachytherapy or helical tomotherapy but skin and pectoral muscle doses were higher than with the other techniques. Our results suggest that helical tomotherapy can serve as an effective means of delivering accelerated partial breast irradiation and may offer superior dose homogeneity compared to HDR brachytherapy.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3