Intensity-Modulated Radiation Therapy Improves the Target Coverage Over 3-D Planning While Meeting Lung Tolerance Doses for All Patients With Malignant Pleural Mesothelioma

Author:

Ulger Sukran1,Cetin Eren1,Catli Serap1,Sarac Hilal1,Kilic Diclehan1,Bora Huseyin1

Affiliation:

1. Department of Radiation Oncology, Faculty of Medicine, Gazi University, Ankara, Turkey

Abstract

Purpose: To investigate high conformality on target coverage and the ability on creating strict lung dose limitation of intensity-modulated radiation therapy in malignant pleural mesothelioma. Patients and Methods: Twenty-four radiation therapy plannings were evaluated and compared with dosimetric outcomes of conformal radiation therapy and intensity-modulated radiation therapy. Hemithoracal radiation therapy was performed on 12 patients with a fraction of 1.8 Gy to a total dose of 50.4 Gy. All organs at risk were contoured. Radiotherapy plannings were differed according to the technique; conformal radiation therapy was planned with conventionally combined photon–electron fields, and intensity-modulated radiation therapy was planned with 7 to 9 radiation beam angles optimized in inverse planning. Strict dose–volume constraints were applied. Results: Intensity-modulated radiation therapy was statistically superior in target coverage and dose homogeneity (intensity-modulated radiation therapy-planning target volume 95 mean 100%; 3-dimensional conformal radiation therapy-planning target volume 95 mean 71.29%, P = .0001; intensity-modulated radiation therapy-planning target volume 105 mean 11.14%; 3-dimensional conformal radiation therapy-planning target volume 105 mean 35.69%, P = .001). The dosimetric results of the remaining lung was below the limitations on intensity-modulated radiation therapy planning data (intensity-modulated radiation therapy-lung mean dose mean 7.5 [range: 5.6%-8.5%]; intensity-modulated radiation therapy-lung V5 mean 55.55% [range: 47%-59.9%]; intensity-modulated radiation therapy-lung V20 mean 4.5% [range: 0.5%-9.5%]; intensity-modulated radiation therapy-lung V13 mean 13.43% [range: 4.2%-22.9%]). Conclusion: With a complex and large target volume of malignant pleural mesothelioma, intensity-modulated radiation therapy has the ability to deliver efficient tumoricidal radiation dose within the safe dose limits of the remaining lung tissue.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3