Development of a Fluorescence Detection System Using Optical Parametric Oscillator (OPO) Laser Excitation for in Vivo Diagnosis

Author:

Song Joon Myong1,Jagannathan Ramesh1,Stokes David L.1,Kasili Paul M.1,Panjehpour Masoud2,Phan Mary N.2,Overholt Bergein F.2,DeNovo Robert C.3,Pan Xiaogang4,Lee Robert J.4,Vo-Dinh Tuan1

Affiliation:

1. Oak Ridge National Laboratory Bethel Valley Road MS-6101, P.O. Box 2008 Oak Ridge, Tennessee 37831-6101

2. Thompson Cancer Survival Center Knoxville, Tennessee 37916

3. Small Animal Clinic College of Veterinary University of Tennessee Knoxville, Tennessee 37916

4. Division of Pharmaceutics College of Pharmacy The Ohio State University 542 LM Parks Hall 500 W. 12th Ave Columbus, Ohio 43210

Abstract

In this work, the development and applications of a fluorescence detection system using optical parametric oscillator (OPO) laser excitation for in vivo disease diagnosis including oral carcinoma are described. The optical diagnosis system was based on an OPO laser for multi-wavelength excitation and time-resolved detection. The pulsed Nd-YAG-pumped OPO laser system (6 ns, 20 Hz) is compact and has a rapid, broad, and uniform tuning range. Time-gated detection of intensified charge-coupled device (ICCD) making use of external triggering was used to effectively eliminate the laser scattering and contribute to the highly sensitive in vivo measurements. Artificial tissue-simulating phantoms consisting of polystyrene microspheres and tissue fluorophores were tested to optimize the gating parameters. 51-ns gate width and 39-ns gate delays were determined to be the optimal parameters for sensitive detection. in vivo measurements with the optical diagnosis system were applied to esophagus, stomach, and small intestine using an endoscope in canine animal studies. The rapid tuning capability of the optical diagnosis system contributed greatly to the optimization of wavelength for the observation of porphyrin in the small intestine. When the small intestine was thoroughly washed with water, the emission band which corresponds to porphyrin disappeared. Based on this observation, it was concluded that the detected signal was yielded by porphyrin-containing bile secretion. Also, multispectral analyses using multiple excitations from 415 to 480 nm at 5 nm intervals confirmed the porphyrin detection in the small intestine. The optical diagnosis system was also applied to the detection of human xenograft of oral carcinoma in mice using 5-aminolevulinic acid (5-ALA) which is a photodynamic therapy (PDT) drug. Significant differences in protoporphyrin IX fluorescence intensity between normal and tumor tissue could be obtained 2 hours after the injection of 5-ALA into mice due to the preferential accumulation of 5-ALA in tumors. Results reported herein demonstrate potential capabilities of the LIF-OPO system for in vivo disease diagnosis.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3