Repositioning Accuracy of a Commercially Available Double-vacuum Whole Body Immobilization System for Stereotactic Body Radiation Therapy

Author:

Fuss Martin1,Salter Bill J.12,Rassiah Premavathy3,Cheek Dennis3,Cavanaugh Sean X.13,Herman Terence S.1

Affiliation:

1. Dept. of Radiation Oncology

2. Cancer Therapy and Research Center 7979 Wurzbach San Antonio, Texas 78229

3. Division of Radiological Sciences University of Texas Health Science Center at San Antonio 7703 Floyd Curl Drive San Antonio, Texas 78229

Abstract

We evaluated the repositioning accuracy of a commercially available stereotactic whole body immobilization system (BodyFIX, Medical Intelligence, Schwabmuenchen, Germany) in 36 patients treated by hypofractionated stereotactic body radiation therapy. CT data were acquired for positional control of patient and tumor before each fraction of the treatment course. Those control CT datasets were compared with the original treatment planning CT simulation and analyzed with respect to positional misalignment of bony patient anatomy, and the respective position of the treated small lung or liver lesions. We assessed the stereotactic coordinates of distinct bony anatomical landmarks in the original CT and each control dataset. In addition, the target isocenter was recorded in the planning CT simulation dataset. An iterative optimization algorithm was implemented, utilizing a root mean square scoring function to determine the best-fit orientation of subsequent sets of anatomical landmark measurements relative to the original treatment planning CT data set. This allowed for the calculation of the x, y and z-components of translation of the patient's body and the target's center-of-mass for each control CT study, as well as rotation about the principal room axes in the respective CT data sets. In addition to absolute patient/target translation, the total magnitude vector of patient and target misalignment was calculated. A clinical assessment determined whether or not the assigned planning target volume safety margins would have provided the desired target coverage. To this end, each control CT study was co-registered with the original treatment planning study using immobilization system related fiducial markers, and the computed isodose calculation was superimposed. In 109 control setup CT scans available for comparison with their respective treatment planning CT simulation study (2–5 per patient, median 3), anatomical landmark analysis revealed a mean bony landmark translation of −0.4 ± 3.9 (mean ± SD), −0.1 ± 1.6 and 0.3 ± 3.6 mm in x, y and z-directions, respectively. Bony landmark setup deviations along one or more principal axis larger than 5 mm were observed in 32 control CT studies (29.4%). Body rotations about the x-, y-and z-axis were 0.9 ± 0.7, 0.8 ± 0.7 and 1.8 ± 1.6 degrees, respectively. Assuming a rigid body relationship of target and bony anatomy, the mean computed absolute target translation was 2.9 ± 3.3, 2.3 ± 2.5 and 3.2 ± 2.7 mm in x, y and z-directions, respectively. The median and mean magnitude vector of target isocenter displacement was computed to be 4.9 mm, and 5.7 ± 3.7 mm. Clinical assessment of PTV/target volume coverage revealed 72 (66.1%), 23 (21.1%), and 14 (12.8%), of excellent (100% isodose coverage), good (>90% isodose coverage), and poor GTV/isodose alignment quality (less than 90% isodose coverage to some aspect of the GTV), respectively. Loss of target volume dose coverage was correlated with translations >5 mm along one or more axes (p<0.0001), rotations >3° about the z-axis (p=0.0007) and body mass index >30 (p<0.0001). The analyzed BodyFIX whole body immobilization system performed favorably compared with other stereotactic body immobilization systems for which peer-reviewed repositioning data exist. While the measured variability in patient and target setup provided clinically acceptable setup accuracy in the vast majority of cases, larger setup deviations were occasional observed. Such deviations constitute a potential for partial target underdosing warranting, in our opinion, a pre-delivery positional assessment procedure (e.g., pre-treatment control CT scan).

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

Cited by 68 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3