Comparison of 2D vs. 3D Dosimetry for Rotte ‘Y’ Applicator High Dose Rate Brachytherapy for Medically Inoperable Endometrial Cancer

Author:

Beriwal Sushil1,Kim Hayeon1,Heron Dwight E.1,Selvaraj Raj1

Affiliation:

1. Department of Radiation Oncology University of Pittsburgh Cancer Institute University of Pittsburgh School of Medicine Pittsburgh, PA 15213, USA

Abstract

The purpose of our research is to compare CT-based volumetric calculations and International Commission on Radiation Units and Measurements (ICRU) reference-point estimates of radiation doses to the target volume, bladder, rectum, and sigmoid colon in patients with carcinoma of the endometrium treated with high dose rate intracavitary Rotte ‘Y’ applicator brachytherapy (HDRB). Eleven patients with cancer of the endometrium were treated with CT-compatible HDR intracavitary Rotte ‘Y’ applicators (Nucletron) and underwent post-implant pelvic CT scans with applicators in place. All patients were treated using orthogonal radiography-based planning. The dose was prescribed to uterine point (a point located 2 cm below the center of a line drawn between the tips of the two ends of the Rotte applicator extending laterally from the tandem by half the maximum uterine width), Point A, and 0.5 cm depth along the upper 3 cm vagina. CT-images were transferred to the PLATO treatment planning system version 14.2.6 and retrospectively planned for volumetric calculations. The clinical target volume (CTV) included the entire uterus, cervix, and upper 3 cm of vagina. The volumes of organs at risk (OAR) were digitized. Dwell positions were identified and registered in both the uterine tandem for each patient. For those receiving HDRB alone, the prescribed dose was 7 Gy x 5 fractions. Patients who were treated following external beam radiation therapy (EBRT) received 4Gy x 5 fractions. The interfraction interval was 6–8 hours. The DVHs were computed for the CTV, bladder, rectum, and sigmoid colon. To compare doses of OARs, 1.0 cc, 2.0 cc, and 5.0 cc volumes receiving the highest dose were calculated from DVHs. 3D optimization was done to improve target coverage and decrease dose to critical organs and compared with the 2D orthogonal radiograph-based plan. The mean of percentage of prescribed dose ± S.D to 1 cc, 2 cc, and 5 cc of the OARs of interest were as follows: Rectum 44 ± 21%, 39 ± 18%, and 33 ± 15%; bladder 104 ± 36%, 91 ± 31%, and 73.9 ± 24%; and sigmoid 124 ± 35%, 109 ± 30%, and 89 ± 25%, respectively. The corresponding dose to ICRU 38 bladder and rectal points were 98 ± 55% and 50.5 ± 32%, respectively. The mean dose to uterine point and point A were 99 ± 1.7% and 98 ± 3%, respectively. The mean CTV volume was 160 ± 89 cc with the percentage of volume getting 100% and 90% of the dose being 62 ± 12% and 68 ± 12% with 2D plan versus 57 ± 8% and 67 ± 8.9% with 3D plan. The dose to critical organs were reduced with 3D optimization for rectum, bladder, and sigmoid by 5.6% (p = 0.04), 20.6% (p = 0.02), and 26.8% (p = 0.005), respectively. Compared to the 3-D volume dose, the prescription points overestimated the dose to the target volume. The under-dosing was because of inability of two channel applicator to cover volumes in the region of the cervix and vagina. The dose to sigmoid colon was high and attention should be given to the sigmoid dose at the time of treatment planning. 3D planning helped in reducing the dose to the critical organs without compromising target coverage. Correlations with outcome are needed to better define the role of 3D dosimetry in treatment planning.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3